Search results
Results from the WOW.Com Content Network
- BD: base down prisms - BU: base up prisms - BO: base out prisms - BI: base in prisms - eso: esotropia - exo: exotropias - L/R: left hypertropia or right hypotropia - R/L: right hypertropia or left hypotropia Double Maddox rod test. The double Maddox rod test can also be used to assess torsion and measure cyclotropias.
The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion.
If test prisms with increasing amount are placed in front of the observer’s eyes, the fixation disparity changes in the eso direction with base-in prisms and in the exo direction with base-out prisms (Fig. 3). These prisms force the eyes to change the vergence angle while the viewing distance remains unchanged.
Esotropia is a form of strabismus in which one or both eyes turn inward. The condition can be constantly present, or occur intermittently, and can give the affected individual a "cross-eyed" appearance. [1] It is the opposite of exotropia and usually involves more severe axis deviation than esophoria. Esotropia is sometimes erroneously called ...
Suppression of an eye is a subconscious adaptation by a person's brain to eliminate the symptoms of disorders of binocular vision such as strabismus, convergence insufficiency and aniseikonia. The brain can eliminate double vision by ignoring all or part of the image of one of the eyes. The area of a person's visual field that is suppressed is ...
Either BASE IN for an exodeviation (eye turned out), BASE OUT for an esodeviation (eye turned in), BASE UP for a hypodeviation (eye turned down) or BASE DOWN for a hyperdeviation (eye turned up). Steps: 1. The patient should be measured in primary position first and then in any other positions of gaze of concern.
Dissociated vertical deviation. Dissociated vertical deviation ( DVD) is an eye condition which occurs in association with a squint, typically infantile esotropia. The exact cause is unknown, although it is logical to assume it is from faulty innervation of eye muscles.
When measuring horizontal fusion ranges, base in prisms assess fusional divergence while base out prisms assess fusional convergence. The vertical fusional vergence amplitude can also be measured with base up and base down prisms although the horizontal PFR is typically the main focus when testing.
Amblyopia. Anisometropia is a condition in which a person's eyes have substantially differing refractive power. [1] Generally, a difference in power of one diopter (1D) is the threshold for diagnosis of the condition . [2] [3] Patients may have up to 3D of anisometropia before the condition becomes clinically significant due to headache, eye ...
Prism correction is measured in prism dioptres. A prescription that specifies prism correction will also specify the "base". The base is the thickest part of the lens and is opposite from the apex. Light will be bent towards the base and the image will be shifted towards the apex.