The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]
Prism lenses (here unusually thick) are used for pre-operative prism adaptation. Eye care professionals use prism correction as a component of some eyeglass prescriptions.A lens which includes some amount of prism correction will displace the viewed image horizontally, vertically, or a combination of both directions.
Duochrome test. A duochrome test is a test commonly used to refine the final sphere in refraction (undercorrection and overcorrection), which makes use of the longitudinal chromatic aberration of the eye. Because of the chromatic aberration of the eye, the shorter wavelengths (green) are focused in front of the longer red wavelengths.
Aberrations of the eye. The eye, like any other optical system, suffers from a number of specific optical aberrations. The optical quality of the eye is limited by optical aberrations, diffraction and scatter. [1] Correction of spherocylindrical refractive errors has been possible for nearly two centuries following Airy's development of methods ...
Vertex distance is the distance between the back surface of a corrective lens, i.e. glasses (spectacles) or contact lenses, and the front of the cornea. Increasing or decreasing the vertex distance changes the optical properties of the system, by moving the focal point forward or backward, effectively changing the power of the lens relative to ...
The Maddox rod test can be used to subjectively detect and measure a latent, manifest, horizontal or vertical strabismus for near and distance. The test is based on the principle of diplopic projection. [1] Dissociation of the deviation is brought about by presenting a red line image to one eye and a white light to the other, while prisms are ...
Cover test. A cover test or cover-uncover test is an objective determination of the presence and amount of ocular deviation. It is typically performed by orthoptists, ophthalmologists and optometrists during eye examinations . The two primary types of cover tests are: the alternating cover test. the unilateral cover test (or the cover-uncover ...
Prism fusion range. The prism fusion range ( PFR) or fusional vergence amplitude is a clinical eye test performed by orthoptists, optometrists, and ophthalmologists to assess motor fusion, specifically the extent to which a patient can maintain binocular single vision ( BSV) in the presence of increasing vergence demands. Motor fusion is ...
assess degree of binocular vision. The Worth Four Light Test, also known as the Worth's four dot test or W4LT, is a clinical test mainly used for assessing a patient's degree of binocular vision and binocular single vision. Binocular vision involves an image being projected by each eye simultaneously into an area in space and being fused into a ...
Lea test. logMAR chart. An eye chart is a chart used to measure visual acuity comprising lines of optotypes in ranges of sizes. Optotypes are the letters or symbols shown on an eye chart. [1] Eye charts are often used by health care professionals, such as optometrists, physicians and nurses, to screen persons for vision impairment.