enow.com Web Search

Search results

    21.57-1.10 (-4.85%)

    at Mon, Jun 3, 2024, 4:00PM EDT - U.S. markets closed

    After Hours 21.85 +0.28 (+1.30%)

    Nasdaq Real Time Price

    • Open 22.81
    • High 23.09
    • Low 21.32
    • Prev. Close 22.67
    • 52 Wk. High 32.00
    • 52 Wk. Low 13.97
    • P/E N/A
    • Mkt. Cap 1.08B
  1. Results from the WOW.Com Content Network
  2. Four prism dioptre reflex test - Wikipedia

    en.wikipedia.org/wiki/Four_prism_dioptre_reflex_test

    Four prism dioptre reflex test. Purpose. assess alignment of both eyes. The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion. [1]

  3. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    Either BASE IN for an exodeviation (eye turned out), BASE OUT for an esodeviation (eye turned in), BASE UP for a hypodeviation (eye turned down) or BASE DOWN for a hyperdeviation (eye turned up). [5] Steps: 1. The patient should be measured in primary position first and then in any other positions of gaze of concern.

  4. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    - BD: base down prisms - BU: base up prisms - BO: base out prisms - BI: base in prisms - eso: esotropia - exo: exotropias - L/R: left hypertropia or right hypotropia - R/L: right hypertropia or left hypotropia Double Maddox rod test. The double Maddox rod test can also be used to assess torsion and measure cyclotropias.

  5. Monofixation syndrome - Wikipedia

    en.wikipedia.org/wiki/Monofixation_syndrome

    Monofixation syndrome ( MFS) (also: microtropia or microstrabismus) is an eye condition defined by less-than-perfect binocular vision. [1] It is defined by a small angle deviation with suppression of the deviated eye and the presence of binocular peripheral fusion. [2] That is, MFS implies peripheral fusion without central fusion.

  6. Esotropia - Wikipedia

    en.wikipedia.org/wiki/Esotropia

    Treatment options for esotropia include glasses to correct refractive errors (see accommodative esotropia below), the use of prisms, orthoptic exercises, or eye muscle surgery. The term is from Greek eso meaning "inward" and trope meaning "a turning".

  7. Prism fusion range - Wikipedia

    en.wikipedia.org/wiki/Prism_fusion_range

    When measuring horizontal fusion ranges, base in prisms assess fusional divergence while base out prisms assess fusional convergence. The vertical fusional vergence amplitude can also be measured with base up and base down prisms although the horizontal PFR is typically the main focus when testing.

  8. Suppression (eye) - Wikipedia

    en.wikipedia.org/wiki/Suppression_(eye)

    Suppression of an eye is a subconscious adaptation by a person's brain to eliminate the symptoms of disorders of binocular vision such as strabismus, convergence insufficiency and aniseikonia. The brain can eliminate double vision by ignoring all or part of the image of one of the eyes. The area of a person's visual field that is suppressed is ...

  9. Hirschberg test - Wikipedia

    en.wikipedia.org/wiki/Hirschberg_test

    The Krimsky test is essentially the Hirschberg test, but with prisms employed to quantitate deviation of ocular misalignment by determining how much prism is required to centre the reflex [2] The Krimsky test is advisably used for patients with tropias, but not with phorias.

  10. Stereopsis recovery - Wikipedia

    en.wikipedia.org/wiki/Stereopsis_recovery

    Stereopsis recovery, also recovery from stereoblindness, is the phenomenon of a stereoblind person gaining partial or full ability of stereo vision ( stereopsis ). Recovering stereo vision as far as possible has long been established as an approach to the therapeutic treatment of stereoblind patients. Treatment aims to recover stereo vision in ...

  11. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Prism correction is measured in prism dioptres. A prescription that specifies prism correction will also specify the "base". The base is the thickest part of the lens and is opposite from the apex. Light will be bent towards the base and the image will be shifted towards the apex.