enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Yoked prism can move the image away from primary gaze without the need for a constant head tilt or turn. Prism correction is measured in prism dioptres. A prescription that specifies prism correction will also specify the "base". The base is the thickest part of the lens and is opposite from the apex.

  3. Esotropia - Wikipedia

    en.wikipedia.org/wiki/Esotropia

    Treatment options for esotropia include glasses to correct refractive errors (see accommodative esotropia below), the use of prisms, orthoptic exercises, or eye muscle surgery. The term is from Greek eso meaning "inward" and trope meaning "a turning".

  4. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    Purpose. measuring strabismus. The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  5. Strabismus - Wikipedia

    en.wikipedia.org/wiki/Strabismus

    Glasses, surgery [3] Frequency. ~2% (children) [3] Strabismus is a vision disorder in which the eyes do not properly align with each other when looking at an object. [2] The eye that is pointed at an object can alternate. [3] The condition may be present occasionally or constantly. [3]

  6. Strabismus surgery - Wikipedia

    en.wikipedia.org/wiki/Strabismus_surgery

    Esotropias measuring more than 15 prism diopters (PD) and exotropias more than 20 PD that have not responded to refractive correction can be considered candidates for surgery. Techniques Disinserting the medial rectus muscle. The goal of strabismus surgery is to correct misalignment of the eyes.

  7. Chirped pulse amplification - Wikipedia

    en.wikipedia.org/wiki/Chirped_pulse_amplification

    In addition to the higher peak power, CPA makes it possible to miniaturize laser systems (the compressor being the biggest part). A compact high-power laser, known as a tabletop terawatt laser (T 3 laser, typically delivering 1 joule of energy within 1 picosecond), can be created based on the CPA technique. Stretcher and compressor design

  8. Corrective lens - Wikipedia

    en.wikipedia.org/wiki/Corrective_lens

    A corrective lens is a transmissive optical device that is worn on the eye to improve visual perception. The most common use is to treat refractive errors: myopia, hypermetropia, astigmatism, and presbyopia. Glasses or "spectacles" are worn on the face a short distance in front of the eye.

  9. Prism (optics) - Wikipedia

    en.wikipedia.org/wiki/Prism_(optics)

    Some laser active media can be formed as a prism where the low-quality pump beam enters the front facet, while the amplified beam undergoes total internal reflection under grazing incidence from it. Such a design suffers less from thermal stress and is easy to be pumped by high-power laser diodes.

  10. Prism compressor - Wikipedia

    en.wikipedia.org/wiki/Prism_compressor

    Prism compressors are typically used to compensate for dispersion inside Ti:sapphire modelocked lasers. Each time the laser pulse inside travels through the optical components inside the laser cavity, it becomes stretched. A prism compressor inside the cavity can be designed such that it exactly compensates this intra-cavity dispersion.

  11. Eyeglass prescription - Wikipedia

    en.wikipedia.org/wiki/Eyeglass_prescription

    Prism and Base Prism refers to a displacement of the image through the lens, often used to treat strabismus and other binocular vision disorders. The prism value is measured in prism diopters , and Base refers to the direction of displacement.