The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]
F3HP and F3/T. Initially, the F3 model with the DE-2 eye-level finder was introduced, soon followed by the popular F3HP, or High Point camera, with the DE-3 High Eyepoint prism/finder. The major advantage of this finder was that the entire viewfinder image could be seen from a distance of 2.5 cm from the viewfinder.
Dissociation of the deviation is brought about by presenting a red line image to one eye and a white light to the other, while prisms are used to superimpose these and effectively measure the angle of deviation (horizontal and vertical).
The most common application for this is the treatment of strabismus. By moving the image in front of the deviated eye, double vision can be avoided and comfortable binocular vision can be achieved. Other applications include yoked prism where the image is shifted an equal amount in each eye.
A duochrome test is a test commonly used to refine the final sphere in refraction (undercorrection and overcorrection), which makes use of the longitudinal chromatic aberration of the eye. Because of the chromatic aberration of the eye, the shorter wavelengths (green) are focused in front of the longer red wavelengths.
The formula for vertex correction is = (), where F c is the power corrected for vertex distance, F is the original lens power, and x is the change in vertex distance in meters.
Prism spectacles with a single prism perform a relative displacement of the two eyes, thereby correcting eso-, exo, hyper- or hypotropia. In contrast, spectacles with prisms of equal power for both eyes, called yoked prisms (also: conjugate prisms , ambient lenses or performance glasses ) shift the visual field of both eyes to the same extent.
Chromatic correction of visible and near infrared wavelengths. Horizontal axis shows degree of aberration, 0 is no aberration. Lenses: 1: simple, 2: achromatic doublet, 3: apochromatic and 4: superachromat. In the earliest uses of lenses, chromatic aberration was reduced by increasing the focal length of the lens where possible.
Correction of spherocylindrical refractive errors has been possible for nearly two centuries following Airy's development of methods to measure and correct ocular astigmatism. It has only recently [ when? ] become possible to measure the aberrations of the eye and with the advent of refractive surgery it might be possible to correct certain ...
Color vision is categorized foremost according to the dimensionality of the color gamut, which is defined by the number of primaries required to represent the color vision. This is generally equal to the number of photopsins expressed: a correlation that holds for vertebrates but not invertebrates.