Search results
Results from the WOW.Com Content Network
The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]
- L/R: left hypertropia or right hypotropia - R/L: right hypertropia or left hypotropia Double Maddox rod test. The double Maddox rod test can also be used to assess torsion and measure cyclotropias. Double Maddox rod test with trial frames. The room lights should be dimmed and only one light source should be visible
Surgical correction of the hypertropia is desired to achieve binocularity, manage diplopia and/or correct the cosmetic defect. Steps to achieve the same depend on mechanism of the hypertropia and identification of the offending muscles causing the misalignment.
Specialty. Neurology. Congenital fourth nerve palsy is a condition present at birth characterized by a vertical misalignment of the eyes due to a weakness or paralysis of the superior oblique muscle. Other names for fourth nerve palsy include superior oblique palsy and trochlear nerve palsy. [1] When looking to the right/left the nerve/muscle ...
Right hypertropia RHypoT or RHT Right hypotropia RNFL Retinal nerve fibre layer RPE Retinal pigment epithelium RSOT Right esotropia Rx Prescription SE Spherical Equivalent: SLE Slit lamp examination SLM Slit lamp microscope EP Esophoria: ET Esotropia: Supp. Suppression V Vision (unaided) VA Visual acuity VA Dcc - VA Dsc
In the fields of optometry and ophthalmology, the Hirschberg test, also Hirschberg corneal reflex test, is a screening test that can be used to assess whether a person has strabismus (ocular misalignment). A photographic version of the Hirschberg is used to quantify strabismus.
Step 1: Determine which eye is hypertropic in primary position. If there is right hypertropia in primary position, then the depressors of the R eye (IR/SO) or the elevators of the L eye are weak (SR/IO). Step 2: Determine whether the hypertropia increases on right or left gaze.
Heterophoria is an eye condition in which the directions that the eyes are pointing at rest position, when not performing binocular fusion, are not the same as each other, or, "not straight". This condition can be esophoria, where the eyes tend to cross inward in the absence of fusion; exophoria, in which they diverge; or hyperphoria, in which ...
It can be used to establish whether a patient has the ability for the eyes to fuse the light that is received from each eye into 4 lights. The test is indicated with the use of a presence of a prism in individuals with a strabismus and fusion is considered present if 4 lights are maintained, with or without the use of a prism. The W4LT can also ...
Prism dioptres. Prism correction is commonly specified in prism dioptres, a unit of angular measurement that is loosely related to the dioptre. Prism dioptres are represented by the Greek symbol delta (Δ) in superscript. A prism of power 1 Δ would produce 1 unit of displacement for an object held 100 units from the prism. [2]