enow.com Web Search

Search results

    25.55-0.44 (-1.69%)

    at Wed, May 29, 2024, 4:00PM EDT - U.S. markets open in 6 hours 58 minutes

    Nasdaq Real Time Price

    • Open 25.53
    • High 26.06
    • Low 25.40
    • Prev. Close 25.99
    • 52 Wk. High 32.00
    • 52 Wk. Low 13.97
    • P/E N/A
    • Mkt. Cap 1.28B
  1. Results from the WOW.Com Content Network
  2. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    Either BASE IN for an exodeviation (eye turned out), BASE OUT for an esodeviation (eye turned in), BASE UP for a hypodeviation (eye turned down) or BASE DOWN for a hyperdeviation (eye turned up). Steps: 1. The patient should be measured in primary position first and then in any other positions of gaze of concern.

  3. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Prism correction is measured in prism dioptres. A prescription that specifies prism correction will also specify the "base". The base is the thickest part of the lens and is opposite from the apex. Light will be bent towards the base and the image will be shifted towards the apex.

  4. Worth 4 dot test - Wikipedia

    en.wikipedia.org/wiki/Worth_4_dot_test

    The test is indicated with the use of a presence of a prism in individuals with a strabismus and fusion is considered present if 4 lights are maintained, with or without the use of a prism. The W4LT can also be indicated when aiding a person to develop and strengthen their fusional capacities.

  5. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    If the patient saw a red line to the left and white light to the right, they are said to have exotropia or exophoria (crossed diplopia) in which base in(BI) prisms of increasing strength are used until the lines are superimposed. Maddox rod test tutorial. Method for measuring vertical deviations: 1.

  6. Maddox wing - Wikipedia

    en.wikipedia.org/wiki/Maddox_Wing

    Relaxation of accommodation can result in an increase in exophoria and a decrease in esophoria, leading to an inaccurate result. The examiner should check the function of the Maddox Wing Instrument before use; the septa can be easily bent, leading to the septa not covering the intended view.

  7. Heterophoria - Wikipedia

    en.wikipedia.org/wiki/Heterophoria

    Optometry Ophthalmology. Heterophoria is an eye condition in which the directions that the eyes are pointing at rest position, when not performing binocular fusion, are not the same as each other, or, "not straight".

  8. Fixation disparity - Wikipedia

    en.wikipedia.org/wiki/Fixation_disparity

    The prism FD-curve (measured subjectively in near vision) tends to have a steeper slope (see Fig. 3b), meaning that the binocular system is not able to reach a small fixation disparity when vergence is forced by prisms in the base-in and base-out direction.

  9. Cover test - Wikipedia

    en.wikipedia.org/wiki/Cover_test

    If the eye was exotropic, covering the fixating eye will cause an inwards movement; and if esotropic, covering the fixating eye will cause an outwards movement. The alternating cover test, or cross cover test is used to detect total deviation (tropia + phoria).

  10. Prism fusion range - Wikipedia

    en.wikipedia.org/wiki/Prism_fusion_range

    The examiner places the prism bar in front of one of the patient's eyes with the prism placed “base in” to assess the fusional divergence amplitude. The divergence amplitude should be measured before convergence, as measuring the convergence amplitude first could contaminate the results of the divergence amplitude since convergence ...

  11. Convergence insufficiency - Wikipedia

    en.wikipedia.org/wiki/Convergence_insufficiency

    Convergence disorder. Specialty. Ophthalmology, optometry. Convergence insufficiency is a sensory and neuromuscular anomaly of the binocular vision system, characterized by a reduced ability of the eyes to turn towards each other, or sustain convergence .