enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Prism correction. Prism lenses (here unusually thick) are used for pre-operative prism adaptation. Eye care professionals use prism correction as a component of some eyeglass prescriptions. A lens which includes some amount of prism correction will displace the viewed image horizontally, vertically, or a combination of both directions.

  3. Anisometropia - Wikipedia

    en.wikipedia.org/wiki/Anisometropia

    The usual recommendation for those needing iseikonic correction is to wear contact lenses. The effect of vertex distance is removed and the effect of center thickness is also almost removed, meaning there is minimal and likely unnoticeable image size difference.

  4. Maddox wing - Wikipedia

    en.wikipedia.org/wiki/Maddox_Wing

    The Maddox Wing test is performed at near with the instrument held in reading position, slightly inferior (approximately 15° depression and 33 cm away). The room or location of the test should be brightly illuminated and the patient's optical correction (e.g. glasses, bifocals, multifocals, contact lens) is required to be worn.

  5. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    If the patient saw a red line to the right and white light to the left, they are said to have esotropia or esophoria (uncrossed diplopia) in which base out (BO) prisms of increasing strength are used until the lines are superimposed.

  6. Esotropia - Wikipedia

    en.wikipedia.org/wiki/Esotropia

    Where appropriate, prismatic correction can be used, either temporarily or permanently, to relieve symptoms of double vision. In specific cases, and primarily in adult patients, botulinum toxin can be used either as a permanent therapeutic approach, or as a temporary measure to prevent contracture of muscles prior to surgery

  7. Prism (optics) - Wikipedia

    en.wikipedia.org/wiki/Prism_(optics)

    Prism spectacles with a single prism perform a relative displacement of the two eyes, thereby correcting eso-, exo, hyper- or hypotropia. In contrast, spectacles with prisms of equal power for both eyes, called yoked prisms (also: conjugate prisms , ambient lenses or performance glasses ) shift the visual field of both eyes to the same extent.

  8. Eyeglass prescription - Wikipedia

    en.wikipedia.org/wiki/Eyeglass_prescription

    Every corrective lens prescription includes a spherical correction in diopters. Convergent powers are positive (e.g., +4.00 D) and condense light to correct for farsightedness/long-sightedness ( hyperopia ) or allow the patient to read more comfortably (see presbyopia and binocular vision disorders ).

  9. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  10. Intraocular lens power calculation - Wikipedia

    en.wikipedia.org/wiki/Intraocular_lens_power...

    In order to determine the power of intraocular lens, several values need to be known: Eye's axial length (AL) Corneal power (K) Postoperative IOL position within the eye known as estimated lens position (ELP) The anterior chamber constant: A-constant or another lens related constant

  11. Esophoria - Wikipedia

    en.wikipedia.org/wiki/Esophoria

    Esophoria is an eye condition involving inward deviation of the eye, usually due to extra-ocular muscle imbalance. It is a type of heterophoria. Cause. Causes include: Refractive errors; Divergence insufficiency; Convergence excess; this can be due to nerve, muscle, congenital or mechanical anomalies.