The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]
A duochrome test is a test commonly used to refine the final sphere in refraction (undercorrection and overcorrection), which makes use of the longitudinal chromatic aberration of the eye. Because of the chromatic aberration of the eye, the shorter wavelengths (green) are focused in front of the longer red wavelengths.
The most common application for this is the treatment of strabismus. By moving the image in front of the deviated eye, double vision can be avoided and comfortable binocular vision can be achieved. Other applications include yoked prism where the image is shifted an equal amount in each eye.
The formula for vertex correction is = (), where F c is the power corrected for vertex distance, F is the original lens power, and x is the change in vertex distance in meters.
Dissociation of the deviation is brought about by presenting a red line image to one eye and a white light to the other, while prisms are used to superimpose these and effectively measure the angle of deviation (horizontal and vertical).
A cross screen filter, also known as a star filter, creates a star pattern, in which lines radiate outward from bright objects. The star pattern is generated by a very fine diffraction grating embedded in the filter, or sometimes by the use of prisms in the filter.
Prism spectacles with a single prism perform a relative displacement of the two eyes, thereby correcting eso-, exo, hyper- or hypotropia. In contrast, spectacles with prisms of equal power for both eyes, called yoked prisms (also: conjugate prisms , ambient lenses or performance glasses ) shift the visual field of both eyes to the same extent.
Subjective refraction. (Top) 0.50 confirmation set; (Middle) trial lens box, including pinhole and occluder; (Bottom) Snellen chart. Subjective Refraction is a technique to determine the combination of lenses that will provide the best corrected visual acuity (BCVA). [1] It is a clinical examination used by orthoptists, optometrists and ...
Since the Howard-Dolman test described above is cumbersome, stereoacuity is usually measured using a stereogram in which separate panels are shown to each eye by superimposing them in a stereoscope using prisms or goggles with color or polarizing filters or alternating occlusion.
The Prentice position is an orientation of a prism, used in optics, optometry and ophthalmology. In this position, named after the optician Charles F. Prentice, the prism is oriented such that light enters it at an angle of 90° to the first surface, so that the beam does not refract at that surface. All the deviation caused by the prism takes ...