enow.com Web Search

Search results

    15.09+0.45 (+3.07%)

    at Fri, May 31, 2024, 4:00PM EDT - U.S. markets closed

    Nasdaq Real Time Price

    • Open 14.77
    • High 15.21
    • Low 14.64
    • Prev. Close 14.64
    • 52 Wk. High 27.02
    • 52 Wk. Low 13.71
    • P/E N/A
    • Mkt. Cap 1.19B
  1. Results from the WOW.Com Content Network
  2. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    measuring strabismus. The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  3. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Prism dioptres. Prism correction is commonly specified in prism dioptres, a unit of angular measurement that is loosely related to the dioptre. Prism dioptres are represented by the Greek symbol delta (Δ) in superscript. A prism of power 1 Δ would produce 1 unit of displacement for an object held 100 units from the prism. [2]

  4. Ocular tonometry - Wikipedia

    en.wikipedia.org/wiki/Ocular_tonometry

    Tonometry is the procedure that eye care professionals perform to determine the intraocular pressure (IOP), the fluid pressure inside the eye. It is an important test in the evaluation of patients at risk from glaucoma.

  5. List of instruments used in ophthalmology - Wikipedia

    en.wikipedia.org/wiki/List_of_instruments_used...

    used in corneal donation (eye donation) to cut out the cornea in a circular fashion Pin-hole: testing visual acuity Red green goggles (red - right side & green - left side) used in Worth 4 dot test, diplopia testing Prisms: to measure the degree of squints; in other instruments; refractive correction; etc. Placido's disc

  6. Prism fusion range - Wikipedia

    en.wikipedia.org/wiki/Prism_fusion_range

    The prism fusion range (PFR) or fusional vergence amplitude is a clinical eye test performed by orthoptists, optometrists, and ophthalmologists to assess motor fusion, specifically the extent to which a patient can maintain binocular single vision in the presence of increasing vergence demands.

  7. Cover test - Wikipedia

    en.wikipedia.org/wiki/Cover_test

    Cover test. A cover test or cover-uncover test is an objective determination of the presence and amount of ocular deviation. It is typically performed by orthoptists, ophthalmologists and optometrists during eye examinations . The two primary types of cover tests are: the unilateral cover test (or the cover-uncover test).

  8. Strabismus surgery - Wikipedia

    en.wikipedia.org/wiki/Strabismus_surgery

    Esotropias measuring more than 15 prism diopters (PD) and exotropias more than 20 PD that have not responded to refractive correction can be considered candidates for surgery. Techniques Disinserting the medial rectus muscle. The goal of strabismus surgery is to correct misalignment of the eyes.

  9. Four prism dioptre reflex test - Wikipedia

    en.wikipedia.org/wiki/Four_prism_dioptre_reflex_test

    The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion.

  10. Fixation disparity - Wikipedia

    en.wikipedia.org/wiki/Fixation_disparity

    Based on prism-FD curves (Fig. 3b), one can find the aligning prism sP 0 that nullifies the naturally prevailing fixation disparity sFD 0. This test procedure is typically made in near vision of 40 cm, e.g. with the Mallett-unit, the Disparometer, or the Wesson card (see above).

  11. Corrective lens - Wikipedia

    en.wikipedia.org/wiki/Corrective_lens

    A pair of contact lenses, positioned with the concave side facing upward. A corrective lens is a transmissive optical device that is worn on the eye to improve visual perception. The most common use is to treat refractive errors: myopia, hypermetropia, astigmatism, and presbyopia.