enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    If the patient saw a red line to the right and white light to the left, they are said to have esotropia or esophoria (uncrossed diplopia) in which base out (BO) prisms of increasing strength are used until the lines are superimposed.

  3. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Prism dioptres. Prism correction is commonly specified in prism dioptres, a unit of angular measurement that is loosely related to the dioptre. Prism dioptres are represented by the Greek symbol delta (Δ) in superscript. A prism of power 1 Δ would produce 1 unit of displacement for an object held 100 units from the prism. [2]

  4. Esotropia - Wikipedia

    en.wikipedia.org/wiki/Esotropia

    Where appropriate, prismatic correction can be used, either temporarily or permanently, to relieve symptoms of double vision. In specific cases, and primarily in adult patients, botulinum toxin can be used either as a permanent therapeutic approach, or as a temporary measure to prevent contracture of muscles prior to surgery

  5. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  6. Strabismus - Wikipedia

    en.wikipedia.org/wiki/Strabismus

    During an eye examination, a test such as cover testing or the Hirschberg test is used in the diagnosis and measurement of strabismus and its impact on vision. Retinal birefringence scanning can be used for screening of young children for eye misalignment. A Cochrane review to examine different types of diagnosis test found only one study.

  7. Fixation disparity - Wikipedia

    en.wikipedia.org/wiki/Fixation_disparity

    Based on prism-FD curves (Fig. 3b), one can find the aligning prism sP 0 that nullifies the naturally prevailing fixation disparity sFD 0. This test procedure is typically made in near vision of 40 cm, e.g. with the Mallett-unit, the Disparometer, or the Wesson card (see above).

  8. Four prism dioptre reflex test - Wikipedia

    en.wikipedia.org/wiki/Four_prism_dioptre_reflex_test

    assess alignment of both eyes. The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion. [1] Through the use of a 4 dioptre base out prism, diplopia is ...

  9. Holm–Bonferroni method - Wikipedia

    en.wikipedia.org/wiki/Holm–Bonferroni_method

    The simple Bonferroni correction rejects only null hypotheses with p-value less than or equal to , in order to ensure that the FWER, i.e., the risk of rejecting one or more true null hypotheses (i.e., of committing one or more type I errors) is at most . The cost of this protection against type I errors is an increased risk of failing to reject ...

  10. Corrective lens - Wikipedia

    en.wikipedia.org/wiki/Corrective_lens

    Corrective lens. A pair of contact lenses, positioned with the concave side facing upward. A corrective lens is a transmissive optical device that is worn on the eye to improve visual perception. The most common use is to treat refractive errors: myopia, hypermetropia, astigmatism, and presbyopia.

  11. Flat-field correction - Wikipedia

    en.wikipedia.org/wiki/Flat-field_correction

    Flat-field correction ( FFC) is a digital imaging technique to mitigate the image detector pixel-to-pixel sensitivity and distortions in the optical path. It is a standard calibration procedure in everything from personal digital cameras to large telescopes.