enow.com Web Search

Search results

    15.09+0.45 (+3.07%)

    at Fri, May 31, 2024, 4:00PM EDT - U.S. markets closed

    Nasdaq Real Time Price

    • Open 14.77
    • High 15.21
    • Low 14.64
    • Prev. Close 14.64
    • 52 Wk. High 27.02
    • 52 Wk. Low 13.71
    • P/E N/A
    • Mkt. Cap 1.19B
  1. Results from the WOW.Com Content Network
  2. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Eye care professionals use prism correction as a component of some eyeglass prescriptions. A lens which includes some amount of prism correction will displace the viewed image horizontally, vertically, or a combination of both directions. The most common application for this is the treatment of strabismus.

  3. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  4. List of optometric abbreviations - Wikipedia

    en.wikipedia.org/wiki/List_of_optometric...

    Description ( notes ) AC. Anterior chamber. fluid-filled space between the iris and the endothelium. AC 4/4. Grade 4 anterior chamber angle. open angle between cornea and iris. AC 3/4. Grade 3 anterior chamber angle.

  5. Ocular tonometry - Wikipedia

    en.wikipedia.org/wiki/Ocular_tonometry

    ICD-9-CM. 89.11. MeSH. D014065. MedlinePlus. 003447. [ edit on Wikidata] Tonometry is the procedure that eye care professionals perform to determine the intraocular pressure (IOP), the fluid pressure inside the eye. It is an important test in the evaluation of patients at risk from glaucoma. [1]

  6. Corrective lens - Wikipedia

    en.wikipedia.org/wiki/Corrective_lens

    Corrective lens. A pair of contact lenses, positioned with the concave side facing upward. A corrective lens is a transmissive optical device that is worn on the eye to improve visual perception. The most common use is to treat refractive errors: myopia, hypermetropia, astigmatism, and presbyopia.

  7. Fixation disparity - Wikipedia

    en.wikipedia.org/wiki/Fixation_disparity

    Fixation disparity. Fixation disparity is a tendency of the eyes to drift in the direction of the heterophoria. While the heterophoria refers to a fusion-free vergence state, the fixation disparity refers to a small misalignment of the visual axes when both eyes are open in an observer with normal fusion and binocular vision. [1]

  8. Hypertropia - Wikipedia

    en.wikipedia.org/wiki/Hypertropia

    Hypertropia is a condition of misalignment of the eyes ( strabismus ), whereby the visual axis of one eye is higher than the fellow fixating eye. Hypotropia is the similar condition, focus being on the eye with the visual axis lower than the fellow fixating eye. Dissociated vertical deviation is a special type of hypertropia leading to slow ...

  9. Aberrations of the eye - Wikipedia

    en.wikipedia.org/wiki/Aberrations_of_the_eye

    Aberrations of the eye. The eye, like any other optical system, suffers from a number of specific optical aberrations. The optical quality of the eye is limited by optical aberrations, diffraction and scatter. [1] Correction of spherocylindrical refractive errors has been possible for nearly two centuries following Airy's development of methods ...

  10. Gonioscopy - Wikipedia

    en.wikipedia.org/wiki/Gonioscopy

    D006068. [ edit on Wikidata] In ophthalmology, gonioscopy is a routine procedure that measures the angle between the iris and the cornea (the iridocorneal angle), using a goniolens (also known as a gonioscope) together with a slit lamp or operating microscope. [1] [2] Its use is important in diagnosing and monitoring various eye conditions ...

  11. Prism (optics) - Wikipedia

    en.wikipedia.org/wiki/Prism_(optics)

    Prism (optics) An optical prism is a transparent optical element with flat, polished surfaces that are designed to refract light. At least one surface must be angled — elements with two parallel surfaces are not prisms. The most familiar type of optical prism is the triangular prism, which has a triangular base and rectangular sides.