Search results
Results from the WOW.Com Content Network
If test prisms with increasing amount are placed in front of the observer’s eyes, the fixation disparity changes in the eso direction with base-in prisms and in the exo direction with base-out prisms (Fig. 3). These prisms force the eyes to change the vergence angle while the viewing distance remains unchanged.
The prism base utilised. For example, Base in (BI), Base out (BO), Base up (BU) or Base down (BD). The angle of the deviation with the units in prism dioptres; Which eye is fixating and which eye is deviating; Whether the test was performed with or without an abnormal head posture; Examples of recording
When measuring horizontal fusion ranges, base in prisms assess fusional divergence while base out prisms assess fusional convergence. The vertical fusional vergence amplitude can also be measured with base up and base down prisms although the horizontal PFR is typically the main focus when testing.
Maddox wing. The Maddox Wing is an instrument utilized by ophthalmologists, orthoptists and optometrists in the measurement of strabismus (misalignment of the eyes; commonly referred to as a squint or lazy eye by the lay person). It is a quantitative and subjective method of measuring the size of a strabismic deviation by dissociation of the ...
Exophoria. Exophoria is a form of heterophoria in which there is a tendency of the eyes to deviate outward. [1] During examination, when the eyes are dissociated, the visual axes will appear to diverge away from one another. [2] The axis deviation in exophoria is usually mild compared with that of exotropia .
- BD: base down prisms - BU: base up prisms - BO: base out prisms - BI: base in prisms - eso: esotropia - exo: exotropias - L/R: left hypertropia or right hypotropia - R/L: right hypertropia or left hypotropia Double Maddox rod test. The double Maddox rod test can also be used to assess torsion and measure cyclotropias.
assess degree of binocular vision. The Worth Four Light Test, also known as the Worth's four dot test or W4LT, is a clinical test mainly used for assessing a patient's degree of binocular vision and binocular single vision. Binocular vision involves an image being projected by each eye simultaneously into an area in space and being fused into a ...
Heterophoria is an eye condition in which the directions that the eyes are pointing at rest position, when not performing binocular fusion, are not the same as each other, or, "not straight". This condition can be esophoria, where the eyes tend to cross inward in the absence of fusion; exophoria, in which they diverge; or hyperphoria, in which ...
Dissociated vertical deviation. Dissociated vertical deviation ( DVD) is an eye condition which occurs in association with a squint, typically infantile esotropia. The exact cause is unknown, although it is logical to assume it is from faulty innervation of eye muscles.
Specialty. Ophthalmology. Exotropia is a form of strabismus where the eyes are deviated outward. It is the opposite of esotropia and usually involves more severe axis deviation than exophoria. People with exotropia often experience crossed diplopia. Intermittent exotropia is a fairly common condition. "Sensory exotropia" occurs in the presence ...