enow.com Web Search

Search results

    21.27-0.30 (-1.39%)

    at Tue, Jun 4, 2024, 4:00PM EDT - U.S. markets closed

    After Hours 22.19 +0.92 (+4.33%)

    Nasdaq Real Time Price

    • Open 21.38
    • High 21.97
    • Low 21.06
    • Prev. Close 21.57
    • 52 Wk. High 32.00
    • 52 Wk. Low 13.97
    • P/E N/A
    • Mkt. Cap 1.08B
  1. Results from the WOW.Com Content Network
  2. Prism fusion range - Wikipedia

    en.wikipedia.org/wiki/Prism_fusion_range

    When measuring horizontal fusion ranges, base in prisms assess fusional divergence while base out prisms assess fusional convergence. The vertical fusional vergence amplitude can also be measured with base up and base down prisms although the horizontal PFR is typically the main focus when testing.

  3. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    Either BASE IN for an exodeviation (eye turned out), BASE OUT for an esodeviation (eye turned in), BASE UP for a hypodeviation (eye turned down) or BASE DOWN for a hyperdeviation (eye turned up). [5] Steps: 1. The patient should be measured in primary position first and then in any other positions of gaze of concern.

  4. Worth 4 dot test - Wikipedia

    en.wikipedia.org/wiki/Worth_4_dot_test

    It can be used to establish whether a patient has the ability for the eyes to fuse the light that is received from each eye into 4 lights. The test is indicated with the use of a presence of a prism in individuals with a strabismus and fusion is considered present if 4 lights are maintained, with or without the use of a prism. The W4LT can also ...

  5. Four prism dioptre reflex test - Wikipedia

    en.wikipedia.org/wiki/Four_prism_dioptre_reflex_test

    assess alignment of both eyes. The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion. [1] Through the use of a 4 dioptre base out prism, diplopia is ...

  6. Exophoria - Wikipedia

    en.wikipedia.org/wiki/Exophoria

    Exophoria. Exophoria is a form of heterophoria in which there is a tendency of the eyes to deviate outward. [1] During examination, when the eyes are dissociated, the visual axes will appear to diverge away from one another. [2] The axis deviation in exophoria is usually mild compared with that of exotropia .

  7. Cover test - Wikipedia

    en.wikipedia.org/wiki/Cover_test

    A cover test or cover-uncover test is an objective determination of the presence and amount of ocular deviation. It is typically performed by orthoptists, ophthalmologists and optometrists during eye examinations . The two primary types of cover tests are: the alternating cover test. the unilateral cover test (or the cover-uncover test).

  8. Fixation disparity - Wikipedia

    en.wikipedia.org/wiki/Fixation_disparity

    If test prisms with increasing amount are placed in front of the observer’s eyes, the fixation disparity changes in the eso direction with base-in prisms and in the exo direction with base-out prisms (Fig. 3).

  9. Maddox wing - Wikipedia

    en.wikipedia.org/wiki/Maddox_Wing

    Maddox wing. The Maddox Wing is an instrument utilized by ophthalmologists, orthoptists and optometrists in the measurement of strabismus (misalignment of the eyes; commonly referred to as a squint or lazy eye by the lay person). It is a quantitative and subjective method of measuring the size of a strabismic deviation by dissociation of the ...

  10. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    - BD: base down prisms - BU: base up prisms - BO: base out prisms - BI: base in prisms - eso: esotropia - exo: exotropias - L/R: left hypertropia or right hypotropia - R/L: right hypertropia or left hypotropia Double Maddox rod test. The double Maddox rod test can also be used to assess torsion and measure cyclotropias.

  11. Botulinum toxin therapy of strabismus - Wikipedia

    en.wikipedia.org/wiki/Botulinum_toxin_therapy_of...

    In a small-scale study, adults whose reading difficulties due to convergence insufficiency had been unsuccessfully addressed by convergence exercises, base-in prism glasses or strabismus surgery showed improved reading after botulinum toxin therapy, maintaining improved reading remaining also after six months. Use as primary therapy