Search results
Results from the WOW.Com Content Network
Prism dioptres. Prism correction is commonly specified in prism dioptres, a unit of angular measurement that is loosely related to the dioptre. Prism dioptres are represented by the Greek symbol delta (Δ) in superscript. A prism of power 1 Δ would produce 1 unit of displacement for an object held 100 units from the prism. [2]
Esophoria is an eye condition involving inward deviation of the eye, usually due to extra-ocular muscle imbalance. It is a type of heterophoria. Cause. Causes include: Refractive errors; Divergence insufficiency; Convergence excess; this can be due to nerve, muscle, congenital or mechanical anomalies.
Vertex distance is the distance between the back surface of a corrective lens, i.e. glasses (spectacles) or contact lenses, and the front of the cornea. Increasing or decreasing the vertex distance changes the optical properties of the system, by moving the focal point forward or backward, effectively changing the power of the lens relative to ...
Heterophoria is the misalignment of the visual axis such that one or both eyes are not properly fixated to an object of interest. When the visual axis is misaligned in such a way, it is corrected by the fusional vergence system. Diagnosis. The cross-cover test, or alternating cover test is usually employed to detect heterophoria.
Jonckheere's trend test. In statistics, the Jonckheere trend test [1] (sometimes called the Jonckheere–Terpstra [2] test) is a test for an ordered alternative hypothesis within an independent samples (between-participants) design. It is similar to the Kruskal-Wallis test in that the null hypothesis is that several independent samples are from ...
https://github.com/casaluca/bolometric-corrections - most up to date tables of bolometric corrections across the HR diagram and interpolation routines in different photometric filters https://web.archive.org/web/20080312151621/http://www.peripatus.gen.nz/Astronomy/SteMag.html - contains table of bolometric corrections
The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]
A cover test or cover-uncover test is an objective determination of the presence and amount of ocular deviation. It is typically performed by orthoptists, ophthalmologists and optometrists during eye examinations . The two primary types of cover tests are: the alternating cover test. the unilateral cover test (or the cover-uncover test).
Formula and usage The formula for Volume Correction Factor is commonly defined as: V C F = C T L = exp { − α T Δ T [ 1 + 0.8 α T ( Δ T + δ T ) ] } {\displaystyle VCF=C_{TL}=\exp\{-\alpha _{T}\Delta T[1+0.8\alpha _{T}(\Delta T+\delta _{T})]\}}
The Prentice position is an orientation of a prism, used in optics, optometry and ophthalmology. In this position, named after the optician Charles F. Prentice, the prism is oriented such that light enters it at an angle of 90° to the first surface, so that the beam does not refract at that surface. All the deviation caused by the prism takes ...