enow.com Web Search

  1. Ads

    related to: esophoria prism correction lens cleaner instructions

Search results

  1. Results from the WOW.Com Content Network
  2. Esophoria - Wikipedia

    en.wikipedia.org/wiki/Esophoria

    Esophoria is an eye condition involving inward deviation of the eye, usually due to extra-ocular muscle imbalance. It is a type of heterophoria. Cause. Causes include: Refractive errors; Divergence insufficiency; Convergence excess; this can be due to nerve, muscle, congenital or mechanical anomalies.

  3. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    The strength of the prism is increased until the streak of the light passes through the centre of the prism, as the strength of the prism indicates the amount of deviation present. The Maddox rod is a handheld instrument composed of red parallel plano convex cylinder lens , which refracts light rays so that a point source of light is seen as a ...

  4. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Prism dioptres. Prism correction is commonly specified in prism dioptres, a unit of angular measurement that is loosely related to the dioptre. Prism dioptres are represented by the Greek symbol delta (Δ) in superscript. A prism of power 1 Δ would produce 1 unit of displacement for an object held 100 units from the prism. [2]

  5. Esotropia - Wikipedia

    en.wikipedia.org/wiki/Esotropia

    Treatment options for esotropia include glasses to correct refractive errors (see accommodative esotropia below), the use of prisms, orthoptic exercises, or eye muscle surgery. The term is from Greek eso meaning "inward" and trope meaning "a turning".

  6. Worth 4 dot test - Wikipedia

    en.wikipedia.org/wiki/Worth_4_dot_test

    It can be used to establish whether a patient has the ability for the eyes to fuse the light that is received from each eye into 4 lights. The test is indicated with the use of a presence of a prism in individuals with a strabismus and fusion is considered present if 4 lights are maintained, with or without the use of a prism. The W4LT can also ...

  7. Convergence insufficiency - Wikipedia

    en.wikipedia.org/wiki/Convergence_insufficiency

    Convergence insufficiency. Convergence Insufficiency. Other names. Convergence disorder. Specialty. Ophthalmology, optometry. Convergence insufficiency is a sensory and neuromuscular anomaly of the binocular vision system, characterized by a reduced ability of the eyes to turn towards each other, or sustain convergence .

  8. Diplopia - Wikipedia

    en.wikipedia.org/wiki/Diplopia

    Surgery or special glasses (prisms) may be advised if there is no recovery in 6 to 12 months. If diplopia turns out to be intractable, it can be managed as last resort by obscuring part of the patient's field of view. This approach is outlined in the article on diplopia occurring in association with a condition called horror fusionis. See also

  9. Heterophoria - Wikipedia

    en.wikipedia.org/wiki/Heterophoria

    Heterophoria is an eye condition in which the directions that the eyes are pointing at rest position, when not performing binocular fusion, are not the same as each other, or, "not straight". This condition can be esophoria, where the eyes tend to cross inward in the absence of fusion; exophoria, in which they diverge; or hyperphoria, in which ...

  10. Subjective refraction - Wikipedia

    en.wikipedia.org/wiki/Subjective_refraction

    Subjective Refraction is a technique to determine the combination of lenses that will provide the best corrected visual acuity (BCVA). [1] It is a clinical examination used by orthoptists, optometrists and ophthalmologists to determine a patient's need for refractive correction, in the form of glasses or contact lenses.

  11. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]