Search results
Results from the WOW.Com Content Network
Thus a prism of 1 Δ would produce 1 cm visible displacement at 100 cm, or 1 meter. This can be represented mathematically as: = where is the amount of prism correction in prism dioptres, and is the angle of deviation of the light.
Heterophoria is the misalignment of the visual axis such that one or both eyes are not properly fixated to an object of interest. When the visual axis is misaligned in such a way, it is corrected by the fusional vergence system. Diagnosis. The cross-cover test, or alternating cover test is usually employed to detect heterophoria.
- BU: base up prisms - BO: base out prisms - BI: base in prisms - eso: esotropia - exo: exotropias - L/R: left hypertropia or right hypotropia - R/L: right hypertropia or left hypotropia Double Maddox rod test. The double Maddox rod test can also be used to assess torsion and measure cyclotropias. Double Maddox rod test with trial frames
Esophoria: ET Esotropia: Supp. Suppression V Vision (unaided) VA Visual acuity VA Dcc - VA Dsc Visual acuity with Distant chart with correctors Visual acuity with eye chart at Distant 20 feet (6 m) and with (cc: Latin cum correctore) correctors (spectacles); Dsc is without (sc: Latin sine correctore) correctors. See Visual_acuity#Legal_definitions
In practice though, this is rarely ever done. The formula for iseikonic lenses (without cylinder) is: Magnification = 1 ( 1 − ( t n ) P ) ⋅ 1 ( 1 − h F ) {\displaystyle {\textrm {Magnification}}={\frac {1}{(1-({\frac {t}{n}})P)}}\cdot {\frac {1}{(1-hF)}}}
Atomic absorption spectroscopy ( AAS) and atomic emission spectroscopy ( AES) is a spectroanalytical procedure for the quantitative determination of chemical elements by free atoms in the gaseous state. Atomic absorption spectroscopy is based on absorption of light by free metallic ions. In analytical chemistry the technique is used for ...
The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]
The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion.
If the eye was exotropic, covering the fixating eye will cause an inwards movement; and if esotropic, covering the fixating eye will cause an outwards movement. The alternating cover test, or cross cover test is used to detect total deviation (tropia + phoria).
The Brown–Forsythe test is a statistical test for the equality of group variances based on performing an Analysis of Variance (ANOVA) on a transformation of the response variable. When a one-way ANOVA is performed, samples are assumed to have been drawn from distributions with equal variance.