The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]
The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion.
Eye care professionals use prism correction as a component of some eyeglass prescriptions. A lens which includes some amount of prism correction will displace the viewed image horizontally, vertically, or a combination of both directions. The most common application for this is the treatment of strabismus.
The prism fusion range (PFR) or fusional vergence amplitude is a clinical eye test performed by orthoptists, optometrists, and ophthalmologists to assess motor fusion, specifically the extent to which a patient can maintain binocular single vision in the presence of increasing vergence demands.
Adjust the spherical component by adding, increasing and refining the power as required. Initially, adjust by 0.50DS, then refine with 0.25DS. When prescribing minus lens correction, it is crucial that the clinician asks the patient if the letters appear clearer or if they appear smaller and darker (If smaller and darker, do not add the extra ...
In a person with normal ocular alignment the light reflex lies slightly nasal from the center of the cornea (approximately 11 prism diopters—or 0.5mm from the pupillary axis), as a result of the cornea acting as a temporally-turned convex mirror to the observer.
Jaeger chart. The Jaeger chart is an eye chart used in testing near vision acuity. It is a card on which paragraphs of text are printed, with the text sizes increasing from 0.37 mm to 2.5 mm. [1] This card is to be held by a patient at a fixed distance from the eye dependent on the J size being read. The smallest print that the patient can read ...
A cover test or cover-uncover test is an objective determination of the presence and amount of ocular deviation. It is typically performed by orthoptists, ophthalmologists and optometrists during eye examinations . The two primary types of cover tests are: the unilateral cover test (or the cover-uncover test).
A Snellen chart is an eye chart that can be used to measure visual acuity. Snellen charts are named after the Dutch ophthalmologist Herman Snellen who developed the chart in 1862 as a measurement tool for the acuity formula developed by his professor Franciscus Cornelius Donders.
Optical power can also be used to adjust a basic prescription for reading. Thus an eye care professional, having determined that a myopic (nearsighted) person requires a basic correction of, say, −2 dioptres to restore normal distance vision, might then make a further prescription of 'add 1' for reading, to make up for lack of accommodation ...