  2. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  3. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    To measure the horizontal deviation, the Maddox rod is placed in front of the right eye (it is done on both eyes) with the cylinder horizontal, making the red line vertical. The patient is then asked whether the white light is superimposed on the red line, or if it is to the left or right of the red line.

  4. Bagolini Striated Glasses Test - Wikipedia

    en.wikipedia.org/wiki/Bagolini_Striated_Glasses_Test

    The glasses are placed in the trial frames with the striations vertical, giving rise to two horizontal line images when viewing a spotlight. If the patient has a vertical deviation, the lines will be seen one above the other. If there is little or no vertical separation, vertical prism can be used to separate the lines.

  5. Prism fusion range - Wikipedia

    en.wikipedia.org/wiki/Prism_fusion_range

    When measuring horizontal fusion ranges, base in prisms assess fusional divergence while base out prisms assess fusional convergence. The vertical fusional vergence amplitude can also be measured with base up and base down prisms although the horizontal PFR is typically the main focus when testing.

  6. Eyeglass prescription - Wikipedia

    en.wikipedia.org/wiki/Eyeglass_prescription

    Sample prescription. A prescription of −1.00 +0.25 × 180 describes a lens that has a horizontal power of −1.00 D and a vertical power of −0.75 D. Only ophthalmologists write prescriptions in + cylinder. An optometrist would write a prescription in - (minus) cylinder.

  7. Fixation disparity - Wikipedia

    en.wikipedia.org/wiki/Fixation_disparity

    This test procedure is typically made in near vision of 40 cm, e.g. with the Mallett-unit, the Disparometer, or the Wesson card (see above). Experimental evidence for the effectiveness of the aligning prism came from a study of reading speed and corresponding preferences of prism eye glasses.

  8. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Eye care professionals use prism correction as a component of some eyeglass prescriptions. A lens which includes some amount of prism correction will displace the viewed image horizontally, vertically, or a combination of both directions.

  9. Subjective refraction - Wikipedia

    en.wikipedia.org/wiki/Subjective_refraction

    It is a clinical examination used by orthoptists, optometrists and ophthalmologists to determine a patient's need for refractive correction, in the form of glasses or contact lenses. The aim is to improve current unaided vision or vision with current glasses. Glasses must also be comfortable visually.

  10. Optometer (ophthalmic instrument) - Wikipedia

    en.wikipedia.org/wiki/Optometer_(ophthalmic...

    The optometer was a device used for measuring the necessary spherical and/or cylindrical corrections to be prescribed for eyeglasses, from the middle of the 18th century until around 1922, when modern instruments were developed.

  11. Prism (optics) - Wikipedia

    en.wikipedia.org/wiki/Prism_(optics)

    An optical prism is a transparent optical element with flat, polished surfaces that are designed to refract light. At least one surface must be angled — elements with two parallel surfaces are not prisms. The most familiar type of optical prism is the triangular prism, which has a triangular base and rectangular sides.