Heterophoria is the misalignment of the visual axis such that one or both eyes are not properly fixated to an object of interest. When the visual axis is misaligned in such a way, it is corrected by the fusional vergence system. Diagnosis. The cross-cover test, or alternating cover test is usually employed to detect heterophoria.
It can be used to establish whether a patient has the ability for the eyes to fuse the light that is received from each eye into 4 lights. The test is indicated with the use of a presence of a prism in individuals with a strabismus and fusion is considered present if 4 lights are maintained, with or without the use of a prism. The W4LT can also ...
The Maddox rod test can be used to subjectively detect and measure a latent, manifest, horizontal or vertical strabismus for near and distance. The test is based on the principle of diplopic projection. [1] Dissociation of the deviation is brought about by presenting a red line image to one eye and a white light to the other, while prisms are ...
If the eye was exotropic, covering the fixating eye will cause an inwards movement; and if esotropic, covering the fixating eye will cause an outwards movement. The alternating cover test, or cross cover test is used to detect total deviation (tropia + phoria).
Exophoria is a form of heterophoria in which there is a tendency of the eyes to deviate outward. During examination, when the eyes are dissociated, the visual axes will appear to diverge away from one another. The axis deviation in exophoria is usually mild compared with that of exotropia.
The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion.
The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]
Prism dioptres. Prism correction is commonly specified in prism dioptres, a unit of angular measurement that is loosely related to the dioptre. Prism dioptres are represented by the Greek symbol delta (Δ) in superscript. A prism of power 1 Δ would produce 1 unit of displacement for an object held 100 units from the prism. [2]
Purpose. whether a person has strabismus. In the fields of optometry and ophthalmology, the Hirschberg test, also Hirschberg corneal reflex test, is a screening test that can be used to assess whether a person has strabismus (ocular misalignment). A photographic version of the Hirschberg is used to quantify strabismus. [1]
Subjective Refraction is a technique to determine the combination of lenses that will provide the best corrected visual acuity (BCVA). [1] It is a clinical examination used by orthoptists, optometrists and ophthalmologists to determine a patient's need for refractive correction, in the form of glasses or contact lenses.