enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  3. Hypertropia - Wikipedia

    en.wikipedia.org/wiki/Hypertropia

    Hypertropia is a condition of misalignment of the eyes ( strabismus ), whereby the visual axis of one eye is higher than the fellow fixating eye. Hypotropia is the similar condition, focus being on the eye with the visual axis lower than the fellow fixating eye. Dissociated vertical deviation is a special type of hypertropia leading to slow ...

  4. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    The strength of the prism is increased until the streak of the light passes through the centre of the prism, as the strength of the prism indicates the amount of deviation present. The Maddox rod is a handheld instrument composed of red parallel plano convex cylinder lens , which refracts light rays so that a point source of light is seen as a ...

  5. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Prism dioptres. Prism correction is commonly specified in prism dioptres, a unit of angular measurement that is loosely related to the dioptre. Prism dioptres are represented by the Greek symbol delta (Δ) in superscript. A prism of power 1 Δ would produce 1 unit of displacement for an object held 100 units from the prism. [2]

  6. Hirschberg test - Wikipedia

    en.wikipedia.org/wiki/Hirschberg_test

    Purpose. whether a person has strabismus. In the fields of optometry and ophthalmology, the Hirschberg test, also Hirschberg corneal reflex test, is a screening test that can be used to assess whether a person has strabismus (ocular misalignment). A photographic version of the Hirschberg is used to quantify strabismus. [1]

  7. Congenital fourth nerve palsy - Wikipedia

    en.wikipedia.org/wiki/Congenital_fourth_nerve_palsy

    Specialty. Neurology. Congenital fourth nerve palsy is a condition present at birth characterized by a vertical misalignment of the eyes due to a weakness or paralysis of the superior oblique muscle. Other names for fourth nerve palsy include superior oblique palsy and trochlear nerve palsy. [1] When looking to the right/left the nerve/muscle ...

  8. Bagolini Striated Glasses Test - Wikipedia

    en.wikipedia.org/wiki/Bagolini_Striated_Glasses_Test

    Purpose. extent of binocular functions. Bagolini striated glasses test, or BSGT, is a subjective clinical test to detect the presence or extent of binocular functions and is generally performed by an optometrist or orthoptist or ophthalmologist (medical/surgical eye doctor). It is mainly used in strabismus clinics.

  9. Cyclotropia - Wikipedia

    en.wikipedia.org/wiki/Cyclotropia

    Cyclotropia is a form of strabismus in which, compared to the correct positioning of the eyes, there is a torsion of one eye (or both) about the eye's visual axis. Consequently, the visual fields of the two eyes appear tilted relative to each other. The corresponding latent condition – a condition in which torsion occurs only in the absence ...

  10. Worth 4 dot test - Wikipedia

    en.wikipedia.org/wiki/Worth_4_dot_test

    assess degree of binocular vision. The Worth Four Light Test, also known as the Worth's four dot test or W4LT, is a clinical test mainly used for assessing a patient's degree of binocular vision and binocular single vision. Binocular vision involves an image being projected by each eye simultaneously into an area in space and being fused into a ...

  11. Four prism dioptre reflex test - Wikipedia

    en.wikipedia.org/wiki/Four_prism_dioptre_reflex_test

    4 dioptre prism, either loose or prism bar; Bright lighting conditions; Method of assessment. As it is an objective test, few instructions are required to be given to the patient. The patient is asked to fixate on a target while the examiner places a 4 prism dioptre base-out prism over the patient's eye, observing the response of the fellow eye.