enow.com Web Search

  1. Ad

    related to: eye prism problems and answers chart

Search results

    15.32-0.15 (-0.97%)

    at Tue, Jun 4, 2024, 4:00PM EDT - U.S. markets open in 7 hours 17 minutes

    Nasdaq Real Time Price

    • Open 15.29
    • High 15.50
    • Low 15.12
    • Prev. Close 15.47
    • 52 Wk. High 27.02
    • 52 Wk. Low 13.71
    • P/E N/A
    • Mkt. Cap 1.2B
  1. Results from the WOW.Com Content Network
  2. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1] Manifest is defined by the eye deviating constantly or intermittently ...

  3. Duochrome test - Wikipedia

    en.wikipedia.org/wiki/Duochrome_test

    A duochrome test is a test commonly used to refine the final sphere in refraction (undercorrection and overcorrection), which makes use of the longitudinal chromatic aberration of the eye. Because of the chromatic aberration of the eye, the shorter wavelengths (green) are focused in front of the longer red wavelengths. It is assumed that best vision is attained when the yellow wavelengths are ...

  4. Aberrations of the eye - Wikipedia

    en.wikipedia.org/wiki/Aberrations_of_the_eye

    For light to converge to a perfect point, the wavefront emerging from the optical system must be a perfect sphere centered on the image point. The distance in micrometers between the actual wavefront and the ideal wavefront is the wavefront aberration, which is the standard method of showing the aberrations of the eye. Therefore, aberrations of the eye are the difference between two surfaces ...

  5. Prism fusion range - Wikipedia

    en.wikipedia.org/wiki/Prism_fusion_range

    The prism fusion range ( PFR) or fusional vergence amplitude is a clinical eye test performed by orthoptists, optometrists, and ophthalmologists to assess motor fusion, specifically the extent to which a patient can maintain binocular single vision ( BSV) in the presence of increasing vergence demands. Motor fusion is largely accounted to amplitudes of fusional vergences and relative fusional ...

  6. Worth 4 dot test - Wikipedia

    en.wikipedia.org/wiki/Worth_4_dot_test

    The Worth Four Light Test, also known as the Worth's four dot test or W4LT, is a clinical test mainly used for assessing a patient's degree of binocular vision and binocular single vision. Binocular vision involves an image being projected by each eye simultaneously into an area in space and being fused into a single image. The Worth Four Light Test is also used in detection of suppression of ...

  7. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Prism correction is measured in prism dioptres. A prescription that specifies prism correction will also specify the "base". The base is the thickest part of the lens and is opposite from the apex. Light will be bent towards the base and the image will be shifted towards the apex. In an eyeglass prescription, the base is typically specified as up, down, in, or out, but left and right are also ...

  8. Stereoscopic acuity - Wikipedia

    en.wikipedia.org/wiki/Stereoscopic_acuity

    Since the Howard-Dolman test described above is cumbersome, stereoacuity is usually measured using a stereogram in which separate panels are shown to each eye by superimposing them in a stereoscope using prisms or goggles with color or polarizing filters or alternating occlusion. [3] A good procedure is a chart, analogous to the familiar Snellen visual acuity chart, in which one letter in each ...

  9. Optical aberration - Wikipedia

    en.wikipedia.org/wiki/Optical_aberration

    In optics, aberration is a property of optical systems, such as lenses, that causes light to be spread out over some region of space rather than focused to a point. [1] Aberrations cause the image formed by a lens to be blurred or distorted, with the nature of the distortion depending on the type of aberration. Aberration can be defined as a departure of the performance of an optical system ...

  10. Stereoscopy - Wikipedia

    en.wikipedia.org/wiki/Stereoscopy

    Stereoscopy creates the illusion of three-dimensional depth from a pair of two-dimensional images. [5] Human vision, including the perception of depth, is a complex process, which only begins with the acquisition of visual information taken in through the eyes; much processing ensues within the brain, as it strives to make sense of the raw information. One of the functions that occur within ...

  11. Snellen chart - Wikipedia

    en.wikipedia.org/wiki/Snellen_chart

    A Snellen chart is an eye chart that can be used to measure visual acuity. Snellen charts are named after the Dutch ophthalmologist Herman Snellen who developed the chart in 1862 as a measurement tool for the acuity formula developed by his professor Franciscus Cornelius Donders. [1] [2] Many ophthalmologists and vision scientists now use an improved chart known as the LogMAR chart .

  1. Ad

    related to: eye prism problems and answers chart