enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Eyeglass prescription - Wikipedia

    en.wikipedia.org/wiki/Eyeglass_prescription

    Sample prescription. A prescription of −1.00 +0.25 × 180 describes a lens that has a horizontal power of −1.00 D and a vertical power of −0.75 D. Only ophthalmologists write prescriptions in + cylinder. An optometrist would write a prescription in - (minus) cylinder. All spectacle and contact lenses would be made in minus cylinder.

  3. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  4. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Prism correction. Prism lenses (here unusually thick) are used for pre-operative prism adaptation. Eye care professionals use prism correction as a component of some eyeglass prescriptions. A lens which includes some amount of prism correction will displace the viewed image horizontally, vertically, or a combination of both directions.

  5. Chromatic aberration - Wikipedia

    en.wikipedia.org/wiki/Chromatic_aberration

    In optics, chromatic aberration ( CA ), also called chromatic distortion and spherochromatism, is a failure of a lens to focus all colors to the same point. [1] It is caused by dispersion: the refractive index of the lens elements varies with the wavelength of light. The refractive index of most transparent materials decreases with increasing ...

  6. Snellen chart - Wikipedia

    en.wikipedia.org/wiki/Snellen_chart

    Acuity charts are used during many kinds of vision examinations, such as "refracting" the eye to determine the best eyeglass prescription. The largest letter on an eye chart often represents an acuity of 6/60 (20/200), the value that is considered "legally blind" in the US.

  7. Progressive lens - Wikipedia

    en.wikipedia.org/wiki/Progressive_lens

    Progressive lenses are corrective lenses used in eyeglasses to correct presbyopia and other disorders of accommodation. They are characterised by a gradient of increasing lens power , added to the wearer's correction for the other refractive errors .

  8. Prism fusion range - Wikipedia

    en.wikipedia.org/wiki/Prism_fusion_range

    When measuring horizontal fusion ranges, base in prisms assess fusional divergence while base out prisms assess fusional convergence. The vertical fusional vergence amplitude can also be measured with base up and base down prisms although the horizontal PFR is typically the main focus when testing.

  9. Autorefractor - Wikipedia

    en.wikipedia.org/wiki/Autorefractor

    An autorefractor or automated refractor is a computer-controlled machine used during an eye examination to provide an objective measurement of a person's refractive error and prescription for glasses or contact lenses. This is achieved by measuring how light is changed as it enters a person's eye.

  10. Fixation disparity - Wikipedia

    en.wikipedia.org/wiki/Fixation_disparity

    Observers with a fixation disparity are more likely to report eye strain in demanding visual tasks; therefore, tests of fixation disparity belong to the diagnostic tools used by eye care professionals: remediation includes vision therapy, prism eye glasses, or visual ergonomics at the workplace.

  11. Bagolini Striated Glasses Test - Wikipedia

    en.wikipedia.org/wiki/Bagolini_Striated_Glasses_Test

    If the patient has a vertical deviation, the lines will be seen one above the other. If there is little or no vertical separation, vertical prism can be used to separate the lines. The patient is asked if one or both lines are tilted.