enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  3. Prism fusion range - Wikipedia

    en.wikipedia.org/wiki/Prism_fusion_range

    The prism fusion range (PFR) or fusional vergence amplitude is a clinical eye test performed by orthoptists, optometrists, and ophthalmologists to assess motor fusion, specifically the extent to which a patient can maintain binocular single vision in the presence of increasing vergence demands.

  4. Four prism dioptre reflex test - Wikipedia

    en.wikipedia.org/wiki/Four_prism_dioptre_reflex_test

    The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion.

  5. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    The Maddox rod test should be used in cases of: Small to moderate (i.e..<25pd) vertical deviations where there is simultaneous perception and normal retinal correspondence (NRC) Decompensated phorias. Acquired strabismus (rather than congenital or early onset) Method of assessment. The method of assessing near and distance fixation is similar.

  6. Fixation disparity - Wikipedia

    en.wikipedia.org/wiki/Fixation_disparity

    Based on prism-FD curves (Fig. 3b), one can find the aligning prism sP 0 that nullifies the naturally prevailing fixation disparity sFD 0. This test procedure is typically made in near vision of 40 cm, e.g. with the Mallett-unit, the Disparometer, or the Wesson card (see above).

  7. Bagolini Striated Glasses Test - Wikipedia

    en.wikipedia.org/wiki/Bagolini_Striated_Glasses_Test

    If there is little or no vertical separation, vertical prism can be used to separate the lines. The patient is asked if one or both lines are tilted. The lines can be straightened subjectively by rotating the glasses in the trial frame and the degree of cyclotropia recorded. Indications for use A video covering the Bagolini Striated Test

  8. Heterophoria - Wikipedia

    en.wikipedia.org/wiki/Heterophoria

    Heterophoria is an eye condition in which the directions that the eyes are pointing at rest position, when not performing binocular fusion, are not the same as each other, or, "not straight". This condition can be esophoria, where the eyes tend to cross inward in the absence of fusion; exophoria, in which they diverge; or hyperphoria, in which ...

  9. Hirschberg test - Wikipedia

    en.wikipedia.org/wiki/Hirschberg_test

    In the fields of optometry and ophthalmology, the Hirschberg test, also Hirschberg corneal reflex test, is a screening test that can be used to assess whether a person has strabismus (ocular misalignment). A photographic version of the Hirschberg is used to quantify strabismus.

  10. Eyeglass prescription - Wikipedia

    en.wikipedia.org/wiki/Eyeglass_prescription

    Sample prescription. A prescription of −1.00 +0.25 × 180 describes a lens that has a horizontal power of −1.00 D and a vertical power of −0.75 D. Only ophthalmologists write prescriptions in + cylinder. An optometrist would write a prescription in - (minus) cylinder.

  11. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Eye care professionals use prism correction as a component of some eyeglass prescriptions. A lens which includes some amount of prism correction will displace the viewed image horizontally, vertically, or a combination of both directions. The most common application for this is the treatment of strabismus.