Search results
Results from the WOW.Com Content Network
Eye care professionals use prism correction as a component of some eyeglass prescriptions. A lens which includes some amount of prism correction will displace the viewed image horizontally, vertically, or a combination of both directions. The most common application for this is the treatment of strabismus.
The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]
Prisms: to measure the degree of squints; in other instruments; refractive correction; etc. Placido's disc: to assess the condition of the corneal surface Retinoscope: objective determination of refractive error and for looking inside the eye Loupe: used to search for magnified examination of the anterior segment of the eye (uniocular or binocular)
Dissociation of the deviation is brought about by presenting a red line image to one eye and a white light to the other, while prisms are used to superimpose these and effectively measure the angle of deviation (horizontal and vertical).
Image orientation correction assembly. This is usually a prism assembly that shortens the optical path. Without this, the image would be inverted and laterally reversed, which is inconvenient for the user. Eyepiece lens assembly. This is the lens assembly near the user's eyes. Its function is to magnify the image.
- News, Politics, Sports, Mail & Latest Headlinesaol.com
A cover test or cover-uncover test is an objective determination of the presence and amount of ocular deviation. It is typically performed by orthoptists, ophthalmologists and optometrists during eye examinations . The two primary types of cover tests are: the alternating cover test. the unilateral cover test (or the cover-uncover test).
It is a clinical examination used by orthoptists, optometrists and ophthalmologists to determine a patient's need for refractive correction, in the form of glasses or contact lenses. The aim is to improve current unaided vision or vision with current glasses.
Prism spectacles with a single prism perform a relative displacement of the two eyes, thereby correcting eso-, exo, hyper- or hypotropia. In contrast, spectacles with prisms of equal power for both eyes, called yoked prisms (also: conjugate prisms, ambient lenses or performance glasses) shift the visual field of both eyes to the same extent.
The Maddox Wing is an instrument utilized by ophthalmologists, orthoptists and optometrists in the measurement of strabismus (misalignment of the eyes; commonly referred to as a squint or lazy eye by the lay person).
The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion.