Search results
Results from the WOW.Com Content Network
Prism correction. Prism lenses (here unusually thick) are used for pre-operative prism adaptation. Eye care professionals use prism correction as a component of some eyeglass prescriptions. A lens which includes some amount of prism correction will displace the viewed image horizontally, vertically, or a combination of both directions.
The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]
Corrective lens. A pair of contact lenses, positioned with the concave side facing upward. A corrective lens is a transmissive optical device that is worn on the eye to improve visual perception. The most common use is to treat refractive errors: myopia, hypermetropia, astigmatism, and presbyopia.
The optical quality of the eye is limited by optical aberrations, diffraction and scatter. [1] Correction of spherocylindrical refractive errors has been possible for nearly two centuries following Airy's development of methods to measure and correct ocular astigmatism.
Diplopia with normal binocular function is treated with prism glasses, botulinum injections into the muscles, or repeated surgery. If binocular function is not normal, a more individualized approach is necessary to best suit the patient's needs.
A cover test or cover-uncover test is an objective determination of the presence and amount of ocular deviation. It is typically performed by orthoptists, ophthalmologists and optometrists during eye examinations . The two primary types of cover tests are: the unilateral cover test (or the cover-uncover test).
Vertex distance is the distance between the back surface of a corrective lens, i.e. glasses (spectacles) or contact lenses, and the front of the cornea. Increasing or decreasing the vertex distance changes the optical properties of the system, by moving the focal point forward or backward, effectively changing the power of the lens relative to ...
In ophthalmology, horror fusionis is a condition in which the eyes have an unsteady deviation, with the extraocular muscles performing spasm-like movements that continuously shift the eyes away from the position in which they would be directed to the same point in space, giving rise to diplopia.
Surgical correction of the hypertropia is desired to achieve binocularity, manage diplopia and/or correct the cosmetic defect. Steps to achieve the same depend on mechanism of the hypertropia and identification of the offending muscles causing the misalignment.
Amblyopia. Anisometropia is a condition in which a person's eyes have substantially differing refractive power. [1] Generally, a difference in power of one diopter (1D) is the threshold for diagnosis of the condition . [2] [3] Patients may have up to 3D of anisometropia before the condition becomes clinically significant due to headache, eye ...