The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]
The most common application for this is the treatment of strabismus. By moving the image in front of the deviated eye, double vision can be avoided and comfortable binocular vision can be achieved. Other applications include yoked prism where the image is shifted an equal amount in each eye.
Strabismus is a vision disorder in which the eyes do not properly align with each other when looking at an object. [2] The eye that is pointed at an object can alternate. [3] The condition may be present occasionally or constantly. [3]
Bagolini striated glasses are glasses of no dioptric power that have many narrow striations running parallel in one meridian. These glasses cause the fixation light to appear as an elongated streak perpendicular to the striations. The lenses are usually placed at 135 degrees in front of the one eye and at 45 degrees in front of the other.
Treatment of the double vision depends on both the type of double vision and the ability of two eyes to work together, also called binocular function. [12] Diplopia with normal binocular function is treated with prism glasses, botulinum injections into the muscles, or repeated surgery. [12]
Today, the injection of botulinum toxin into the muscles that surround the eyes is one of the available options in the management of strabismus. Other options for strabismus management are vision therapy and occlusion therapy, corrective glasses (or contact lenses) and prism glasses, and strabismus surgery .
The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion. [1]
The cover test is regarded as an essential examination in investigating strabismus. It is simple to undertake, does not require great amounts of skill by the examiner and is objective in nature. To ensure that the test is executed accurately and that the maximal amount of information is obtained, it is paramount that the appropriate fixation targets are used for near (approximately 33 cm (13 ...
Dissociation of the deviation is brought about by presenting a red line image to one eye and a white light to the other, while prisms are used to superimpose these and effectively measure the angle of deviation (horizontal and vertical).
Spherical lenses and miotic eye drops can provide relief in some types of horizontal strabismus by biasing the neural link between convergence (orienting the lines of sight for near objects) and accommodation (focusing), and prism lenses can relieve diplopia (double vision) by refracting the visual axis, [30] [unreliable medical source] [31] ...