Search results
Results from the WOW.Com Content Network
Either BASE IN for an exodeviation (eye turned out), BASE OUT for an esodeviation (eye turned in), BASE UP for a hypodeviation (eye turned down) or BASE DOWN for a hyperdeviation (eye turned up). [5] Steps: 1. The patient should be measured in primary position first and then in any other positions of gaze of concern.
When measuring horizontal fusion ranges, base in prisms assess fusional divergence while base out prisms assess fusional convergence. The vertical fusional vergence amplitude can also be measured with base up and base down prisms although the horizontal PFR is typically the main focus when testing.
If test prisms with increasing amount are placed in front of the observer’s eyes, the fixation disparity changes in the eso direction with base-in prisms and in the exo direction with base-out prisms (Fig. 3). These prisms force the eyes to change the vergence angle while the viewing distance remains unchanged.
If the eye was exotropic, covering the fixating eye will cause an inwards movement; and if esotropic, covering the fixating eye will cause an outwards movement. The alternating cover test, or cross cover test is used to detect total deviation (tropia + phoria).
If the patient saw a red line to the left and white light to the right, they are said to have exotropia or exophoria (crossed diplopia) in which base in (BI) prisms of increasing strength are used until the lines are superimposed. [5] Maddox rod test tutorial. Method for measuring vertical deviations:
Exophoria is a form of heterophoria in which there is a tendency of the eyes to deviate outward. During examination, when the eyes are dissociated, the visual axes will appear to diverge away from one another. The axis deviation in exophoria is usually mild compared with that of exotropia.
Relaxation of accommodation can result in an increase in exophoria and a decrease in esophoria, leading to an inaccurate result. The examiner should check the function of the Maddox Wing Instrument before use; the septa can be easily bent, leading to the septa not covering the intended view.
Convergence insufficiency is characterized by one or more of the following diagnostic findings: patient symptoms, high exophoria at near, reduced accommodative convergence/accommodation ratio, receded near point of convergence, and low fusional vergence ranges and/or facility. Some patients with convergence insufficiency have concurrent ...
Optometry Ophthalmology. Heterophoria is an eye condition in which the directions that the eyes are pointing at rest position, when not performing binocular fusion, are not the same as each other, or, "not straight".
Prism spectacles with a single prism perform a relative displacement of the two eyes, thereby correcting eso-, exo, hyper- or hypotropia. In contrast, spectacles with prisms of equal power for both eyes, called yoked prisms (also: conjugate prisms , ambient lenses or performance glasses ) shift the visual field of both eyes to the same extent.