enow.com Web Search

Search results

    31.92+0.75 (+2.41%)

    at Tue, May 28, 2024, 4:00PM EDT - U.S. markets open in 1 hour 22 minutes

    Pre Mkt 30.33 -1.59 (-4.98%)

    Nasdaq Real Time Price

    • Ask Price 49.81
    • Bid Price 0.00
    • P/E N/A
    • 52 Wk. High 40.99
    • 52 Wk. Low 27.59
    • Mkt. Cap 1.5B
  1. Results from the WOW.Com Content Network
  2. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  3. Hypertropia - Wikipedia

    en.wikipedia.org/wiki/Hypertropia

    Correction of refractive errors by glasses; Prism therapy (if tolerated, to manage diplopia) Vision Therapy; Patching (mainly to manage amblyopia in children and diplopia in adults) Botulinum toxin injection; Surgical correction; Surgical correction of the hypertropia is desired to achieve binocularity, manage diplopia and/or correct the ...

  4. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Prism dioptres. Prism correction is commonly specified in prism dioptres, a unit of angular measurement that is loosely related to the dioptre. Prism dioptres are represented by the Greek symbol delta (Δ) in superscript. A prism of power 1 Δ would produce 1 unit of displacement for an object held 100 units from the prism. [2]

  5. Hirschberg test - Wikipedia

    en.wikipedia.org/wiki/Hirschberg_test

    For an abnormal result, based on where the light lands on the cornea, the examiner can detect if there is an exotropia (abnormal eye is turned out), esotropia (abnormal eye is turned in), hypertropia (abnormal eye higher than the normal one) or hypotropia (abnormal eye is lower than the normal one).

  6. Congenital fourth nerve palsy - Wikipedia

    en.wikipedia.org/wiki/Congenital_fourth_nerve_palsy

    Specialty. Neurology. Congenital fourth nerve palsy is a condition present at birth characterized by a vertical misalignment of the eyes due to a weakness or paralysis of the superior oblique muscle. Other names for fourth nerve palsy include superior oblique palsy and trochlear nerve palsy. [1] When looking to the right/left the nerve/muscle ...

  7. Strabismus surgery - Wikipedia

    en.wikipedia.org/wiki/Strabismus_surgery

    Esotropias measuring more than 15 prism diopters (PD) and exotropias more than 20 PD that have not responded to refractive correction can be considered candidates for surgery. Techniques Disinserting the medial rectus muscle. The goal of strabismus surgery is to correct misalignment of the eyes.

  8. Prism (optics) - Wikipedia

    en.wikipedia.org/wiki/Prism_(optics)

    Prism spectacles with a single prism perform a relative displacement of the two eyes, thereby correcting eso-, exo, hyper- or hypotropia. In contrast, spectacles with prisms of equal power for both eyes, called yoked prisms (also: conjugate prisms, ambient lenses or performance glasses) shift the visual field of both eyes to the same extent.

  9. Worth 4 dot test - Wikipedia

    en.wikipedia.org/wiki/Worth_4_dot_test

    assess degree of binocular vision. The Worth Four Light Test, also known as the Worth's four dot test or W4LT, is a clinical test mainly used for assessing a patient's degree of binocular vision and binocular single vision. Binocular vision involves an image being projected by each eye simultaneously into an area in space and being fused into a ...

  10. PRISM model checker - Wikipedia

    en.wikipedia.org/wiki/PRISM_model_checker

    PRISM model checker. PRISM is a probabilistic model checker, a formal verification software tool for the modelling and analysis of systems that exhibit probabilistic behaviour. [1] One source of such systems is the use of randomization, for example in communication protocols like Bluetooth and FireWire, or in security protocols such as Crowds ...

  11. Bagolini Striated Glasses Test - Wikipedia

    en.wikipedia.org/wiki/Bagolini_Striated_Glasses_Test

    Purpose. extent of binocular functions. Bagolini striated glasses test, or BSGT, is a subjective clinical test to detect the presence or extent of binocular functions and is generally performed by an optometrist or orthoptist or ophthalmologist (medical/surgical eye doctor). It is mainly used in strabismus clinics.