enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Yoked prism can move the image away from primary gaze without the need for a constant head tilt or turn. Prism correction is measured in prism dioptres. A prescription that specifies prism correction will also specify the "base". The base is the thickest part of the lens and is opposite from the apex.

  3. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  4. Vision therapy - Wikipedia

    en.wikipedia.org/wiki/Vision_therapy

    Prisms for near binocular disorders and for producing postural change – the use of "yoked" prisms to redirect a person's gaze and bring about a range of claimed benefits including postural improvements and increased wellbeing. There is a lack of evidence for the effect this approach may have.

  5. Hirschberg test - Wikipedia

    en.wikipedia.org/wiki/Hirschberg_test

    In the fields of optometry and ophthalmology, the Hirschberg test, also Hirschberg corneal reflex test, is a screening test that can be used to assess whether a person has strabismus (ocular misalignment). A photographic version of the Hirschberg is used to quantify strabismus.

  6. Prism (optics) - Wikipedia

    en.wikipedia.org/wiki/Prism_(optics)

    Prism spectacles with a single prism perform a relative displacement of the two eyes, thereby correcting eso-, exo, hyper- or hypotropia. In contrast, spectacles with prisms of equal power for both eyes, called yoked prisms (also: conjugate prisms, ambient lenses or performance glasses) shift the visual field of both eyes to the same extent.

  7. Eyeglass prescription - Wikipedia

    en.wikipedia.org/wiki/Eyeglass_prescription

    Sample prescription. A prescription of −1.00 +0.25 × 180 describes a lens that has a horizontal power of −1.00 D and a vertical power of −0.75 D. Only ophthalmologists write prescriptions in + cylinder. An optometrist would write a prescription in - (minus) cylinder.

  8. Homonymous hemianopsia - Wikipedia

    en.wikipedia.org/wiki/Homonymous_hemianopsia

    Prisms or "field expanders" that bend light have been prescribed for decades in patients with hemianopsia. Higher power Fresnel ("stick-on") prisms are commonly employed because they are thin and lightweight, and can be cut and placed in different positions on a spectacle lens.

  9. Four prism dioptre reflex test - Wikipedia

    en.wikipedia.org/wiki/Four_prism_dioptre_reflex_test

    The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion.

  10. Phoropter - Wikipedia

    en.wikipedia.org/wiki/Phoropter

    The major components of the phoropter are the battery of spherical and cylindrical lenses, auxiliary devices such as Maddox rods, filtered lenses, prisms, and the JCC (Jackson cross cylinder) used for astigmatism measurement. The prismatic lenses are used to analyze binocular vision and treat orthoptic problems.

  11. Fixation disparity - Wikipedia

    en.wikipedia.org/wiki/Fixation_disparity

    Based on prism-FD curves (Fig. 3b), one can find the aligning prism sP 0 that nullifies the naturally prevailing fixation disparity sFD 0. This test procedure is typically made in near vision of 40 cm, e.g. with the Mallett-unit, the Disparometer, or the Wesson card (see above).