enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    The Maddox rod test can be used to subjectively detect and measure a latent, manifest, horizontal or vertical strabismus for near and distance. The test is based on the principle of diplopic projection. [1] Dissociation of the deviation is brought about by presenting a red line image to one eye and a white light to the other, while prisms are used to superimpose these and effectively measure ...

  3. Maddox wing - Wikipedia

    en.wikipedia.org/wiki/Maddox_Wing

    The Maddox Wing is an instrument utilized by ophthalmologists, orthoptists and optometrists in the measurement of strabismus (misalignment of the eyes; commonly referred to as a squint or lazy eye by the lay person). It is a quantitative and subjective method of measuring the size of a strabismic deviation by dissociation of the eyes brought about by two septa which are placed in such a way as ...

  4. Worth 4 dot test - Wikipedia

    en.wikipedia.org/wiki/Worth_4_dot_test

    The Worth Four Light Test, also known as the Worth's four dot test or W4LT, is a clinical test mainly used for assessing a patient's degree of binocular vision and binocular single vision. Binocular vision involves an image being projected by each eye simultaneously into an area in space and being fused into a single image. The Worth Four Light Test is also used in detection of suppression of ...

  5. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Prism correction is measured in prism dioptres. A prescription that specifies prism correction will also specify the "base". The base is the thickest part of the lens and is opposite from the apex. Light will be bent towards the base and the image will be shifted towards the apex. In an eyeglass prescription, the base is typically specified as up, down, in, or out, but left and right are also ...

  6. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    This video demonstrates what is involved when performing a prism cover test. Purpose. measuring strabismus. The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the ...

  7. Esophoria - Wikipedia

    en.wikipedia.org/wiki/Esophoria

    Specialty. Ophthalmology. Esophoria is an eye condition involving inward deviation of the eye, usually due to extra-ocular muscle imbalance. It is a type of heterophoria .

  8. Four prism dioptre reflex test - Wikipedia

    en.wikipedia.org/wiki/Four_prism_dioptre_reflex_test

    The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion. [1] Through the use of a 4 dioptre base out prism, diplopia is induced which is the driving force for the eyes to change fixation and therefore re ...

  9. Esotropia - Wikipedia

    en.wikipedia.org/wiki/Esotropia

    Treatment options for esotropia include glasses to correct refractive errors (see accommodative esotropia below), the use of prisms, orthoptic exercises, or eye muscle surgery. The term is from Greek eso meaning "inward" and trope meaning "a turning". [2]

  10. Strabismus - Wikipedia

    en.wikipedia.org/wiki/Strabismus

    Strabismus is a vision disorder in which the eyes do not properly align with each other when looking at an object. [2] The eye that is pointed at an object can alternate. [3] The condition may be present occasionally or constantly. [3] If present during a large part of childhood, it may result in amblyopia, or lazy eyes, and loss of depth perception. [3] If onset is during adulthood, it is ...

  11. Anisometropia - Wikipedia

    en.wikipedia.org/wiki/Anisometropia

    Anisometropia is a condition in which a person's eyes have substantially differing refractive power. [1] Generally, a difference in power of one diopter (1D) is the threshold for diagnosis of the condition . [2] [3] Patients may have up to 3D of anisometropia before the condition becomes clinically significant due to headache, eye strain, double vision or photophobia. [4]