Search results
Results from the WOW.Com Content Network
Eye care professionals use prism correction as a component of some eyeglass prescriptions. A lens which includes some amount of prism correction will displace the viewed image horizontally, vertically, or a combination of both directions. The most common application for this is the treatment of strabismus.
The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]
Visual acuity with eye chart at Near 15.7 inches (400 mm) and without (sc: Latin sine correctore) correctors (spectacles); Ncc is with (cc: Latin cum correctore) correctors. See Visual_acuity#Legal_definitions: VA OS Left visual acuity VA OD Right visual acuity VDU Visual display unit VF Visual field VPS Variable prism stereoscope WD
to correct refractive errors of the eye; a little invasive. Phoropter. used in refraction testing. Tonometers. used to determine the intraoccular pressure (IOP) - useful in glaucoma; video link for various types of tonometers. Speculum: to keep the eyes open during any operation. Universal eye speculum.
The distance in micrometers between the actual wavefront and the ideal wavefront is the wavefront aberration, which is the standard method of showing the aberrations of the eye. Therefore, aberrations of the eye are the difference between two surfaces: the ideal and the actual wavefront.
Prism and Base Prism refers to a displacement of the image through the lens, often used to treat strabismus and other binocular vision disorders. The prism value is measured in prism diopters, and Base refers to the direction of displacement. PL is an abbreviation for plano or plain, meaning no prescription
Prism spectacles with a single prism perform a relative displacement of the two eyes, thereby correcting eso-, exo, hyper- or hypotropia. In contrast, spectacles with prisms of equal power for both eyes, called yoked prisms (also: conjugate prisms , ambient lenses or performance glasses ) shift the visual field of both eyes to the same extent.
A cover test or cover-uncover test is an objective determination of the presence and amount of ocular deviation. It is typically performed by orthoptists, ophthalmologists and optometrists during eye examinations . The two primary types of cover tests are: the alternating cover test. the unilateral cover test (or the cover-uncover test).
A duochrome test is a test commonly used to refine the final sphere in refraction (undercorrection and overcorrection), which makes use of the longitudinal chromatic aberration of the eye. Because of the chromatic aberration of the eye, the shorter wavelengths (green) are focused in front of the longer red wavelengths.
The Prentice position is an orientation of a prism, used in optics, optometry and ophthalmology. In this position, named after the optician Charles F. Prentice , the prism is oriented such that light enters it at an angle of 90° to the first surface, so that the beam does not refract at that surface.