enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Maddox wing - Wikipedia

    en.wikipedia.org/wiki/Maddox_Wing

    The Maddox Wing test is performed at near with the instrument held in reading position, slightly inferior (approximately 15° depression and 33 cm away). The room or location of the test should be brightly illuminated and the patient's optical correction (e.g. glasses, bifocals, multifocals, contact lens) is required to be worn.

  3. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    If the patient saw a red line to the left and white light to the right, they are said to have exotropia or exophoria (crossed diplopia) in which base in (BI) prisms of increasing strength are used until the lines are superimposed. [5] Maddox rod test tutorial. Method for measuring vertical deviations:

  4. Worth 4 dot test - Wikipedia

    en.wikipedia.org/wiki/Worth_4_dot_test

    The test is indicated with the use of a presence of a prism in individuals with a strabismus and fusion is considered present if 4 lights are maintained, with or without the use of a prism. The W4LT can also be indicated when aiding a person to develop and strengthen their fusional capacities.

  5. Welcome to the AI dystopia no one asked for, courtesy of ...

    www.aol.com/welcome-ai-dystopia-no-one-100003592...

    AI skeptics — who are legion, and not necessarily part of the fringe tin foil hat crowd — are begging Silicon Valley to take a beat before unleashing AI to the world. But tech companies, faced ...

  6. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Prism correction is measured in prism dioptres. A prescription that specifies prism correction will also specify the "base". The base is the thickest part of the lens and is opposite from the apex. Light will be bent towards the base and the image will be shifted towards the apex.

  7. Esotropia - Wikipedia

    en.wikipedia.org/wiki/Esotropia

    Treatment options for esotropia include glasses to correct refractive errors (see accommodative esotropia below), the use of prisms, orthoptic exercises, or eye muscle surgery. The term is from Greek eso meaning "inward" and trope meaning "a turning".

  8. Anisometropia - Wikipedia

    en.wikipedia.org/wiki/Anisometropia

    The usual recommendation for those needing iseikonic correction is to wear contact lenses. The effect of vertex distance is removed and the effect of center thickness is also almost removed, meaning there is minimal and likely unnoticeable image size difference.

  9. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  10. Digital room correction - Wikipedia

    en.wikipedia.org/wiki/Digital_room_correction

    Digital room correction (or DRC) is a process in the field of acoustics where digital filters designed to ameliorate unfavorable effects of a room's acoustics are applied to the input of a sound reproduction system.

  11. Fixation disparity - Wikipedia

    en.wikipedia.org/wiki/Fixation_disparity

    The latter prism needed to reduce the fixation disparity to zero is referred to as aligning prism (earlier called associated phoria). Instrumentations as the Disparometer, the Mallett-unit, or the Wesson Card differ in the type of fusion target: some use small central fixation letters, others use more peripheral fusion targets.