Ads
related to: eye prism correction fluid for dogs
Search results
Results from the WOW.Com Content Network
ICD-9-CM. 89.11. MeSH. D014065. MedlinePlus. 003447. [ edit on Wikidata] Tonometry is the procedure that eye care professionals perform to determine the intraocular pressure (IOP), the fluid pressure inside the eye. It is an important test in the evaluation of patients at risk from glaucoma. [1]
The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]
Prism dioptres. Prism correction is commonly specified in prism dioptres, a unit of angular measurement that is loosely related to the dioptre. Prism dioptres are represented by the Greek symbol delta (Δ) in superscript. A prism of power 1 Δ would produce 1 unit of displacement for an object held 100 units from the prism. [2]
Sixth nerve palsy, or abducens nerve palsy, is a disorder associated with dysfunction of cranial nerve VI (the abducens nerve ), which is responsible for causing contraction of the lateral rectus muscle to abduct (i.e., turn out) the eye. [1] The inability of an eye to turn outward, results in a convergent strabismus or esotropia of which the ...
Strabismus is a vision disorder in which the eyes do not properly align with each other when looking at an object. The eye that is pointed at an object can alternate. The condition may be present occasionally or constantly. If present during a large part of childhood, it may result in amblyopia, or lazy eyes, and loss of depth perception.
Efforts must first be made to identify and treat the underlying cause of the problem. Treatment options include eye exercises, wearing an eye patch on alternative eyes, prism correction, and in more extreme situations, surgery or botulinum toxin.
Ophthalmic viscosurgical devices (OVDs) are a class of clear gel-like material used in eye surgery to maintain the volume and shape of the anterior chamber of the eye, and protect the intraocular tissues during the procedure. They were originally called viscoelastic substances, or just viscoelastics. Their consistency allows the surgical ...
assess alignment of both eyes. The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion. [1] Through the use of a 4 dioptre base out prism, diplopia is ...
Corrective lens. A pair of contact lenses, positioned with the concave side facing upward. A corrective lens is a transmissive optical device that is worn on the eye to improve visual perception. The most common use is to treat refractive errors: myopia, hypermetropia, astigmatism, and presbyopia.
D006068. [ edit on Wikidata] In ophthalmology, gonioscopy is a routine procedure that measures the angle between the iris and the cornea (the iridocorneal angle), using a goniolens (also known as a gonioscope) together with a slit lamp or operating microscope. [1] [2] Its use is important in diagnosing and monitoring various eye conditions ...