enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  3. Bagolini Striated Glasses Test - Wikipedia

    en.wikipedia.org/wiki/Bagolini_Striated_Glasses_Test

    If the patient has a vertical deviation, the lines will be seen one above the other. If there is little or no vertical separation, vertical prism can be used to separate the lines. The patient is asked if one or both lines are tilted.

  4. Prism (optics) - Wikipedia

    en.wikipedia.org/wiki/Prism_(optics)

    An optical prism is a transparent optical element with flat, polished surfaces that are designed to refract light. At least one surface must be angled — elements with two parallel surfaces are not prisms. The most familiar type of optical prism is the triangular prism, which has a triangular base and rectangular sides.

  5. Eyeglass prescription - Wikipedia

    en.wikipedia.org/wiki/Eyeglass_prescription

    Prism and Base Prism refers to a displacement of the image through the lens, often used to treat strabismus and other binocular vision disorders. The prism value is measured in prism diopters , and Base refers to the direction of displacement.

  6. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Eye care professionals use prism correction as a component of some eyeglass prescriptions. A lens which includes some amount of prism correction will displace the viewed image horizontally, vertically, or a combination of both directions.

  7. Prism fusion range - Wikipedia

    en.wikipedia.org/wiki/Prism_fusion_range

    When measuring horizontal fusion ranges, base in prisms assess fusional divergence while base out prisms assess fusional convergence. The vertical fusional vergence amplitude can also be measured with base up and base down prisms although the horizontal PFR is typically the main focus when testing.

  8. Prism adaptation - Wikipedia

    en.wikipedia.org/wiki/Prism_Adaptation

    During prism adaptation, an individual wears special prismatic goggles that are made of prism wedges that displace the visual field laterally or vertically. In most cases the visual field is shifted laterally either in the rightward or leftward direction.

  9. Upside down goggles - Wikipedia

    en.wikipedia.org/wiki/Upside_down_goggles

    Upside down goggles, also known as "invertoscopes" by Russian researchers, [1] are optical instruments that invert the image received by the retinas upside down. They are used to study human visual perception, particularly psychological process of building a visual image in the brain.

  10. Aberrations of the eye - Wikipedia

    en.wikipedia.org/wiki/Aberrations_of_the_eye

    The distance in micrometers between the actual wavefront and the ideal wavefront is the wavefront aberration, which is the standard method of showing the aberrations of the eye. Therefore, aberrations of the eye are the difference between two surfaces: the ideal and the actual wavefront.

  11. Worth 4 dot test - Wikipedia

    en.wikipedia.org/wiki/Worth_4_dot_test

    The test is indicated with the use of a presence of a prism in individuals with a strabismus and fusion is considered present if 4 lights are maintained, with or without the use of a prism. The W4LT can also be indicated when aiding a person to develop and strengthen their fusional capacities.