enow.com Web Search

  1. Ad

    related to: esophoria prism correction test kit cost list

Search results

  1. Results from the WOW.Com Content Network
  2. Worth 4 dot test - Wikipedia

    en.wikipedia.org/wiki/Worth_4_dot_test

    The test is indicated with the use of a presence of a prism in individuals with a strabismus and fusion is considered present if 4 lights are maintained, with or without the use of a prism.

  3. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1] Manifest is defined by the eye deviating constantly or intermittently ...

  4. Cover test - Wikipedia

    en.wikipedia.org/wiki/Cover_test

    A cover test or cover-uncover test is an objective determination of the presence and amount of ocular deviation. It is typically performed by orthoptists, ophthalmologists and optometrists during eye examinations . The two primary types of cover tests are: the alternating cover test. the unilateral cover test (or the cover-uncover test).

  5. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    The Maddox rod test can be used to subjectively detect and measure a latent, manifest, horizontal or vertical strabismus for near and distance. The test is based on the principle of diplopic projection. [1] Dissociation of the deviation is brought about by presenting a red line image to one eye and a white light to the other, while prisms are used to superimpose these and effectively measure ...

  6. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Prism correction is measured in prism dioptres. A prescription that specifies prism correction will also specify the "base". The base is the thickest part of the lens and is opposite from the apex. Light will be bent towards the base and the image will be shifted towards the apex. In an eyeglass prescription, the base is typically specified as up, down, in, or out, but left and right are also ...

  7. Maddox wing - Wikipedia

    en.wikipedia.org/wiki/Maddox_Wing

    The Maddox Wing is an instrument utilized by ophthalmologists, orthoptists and optometrists in the measurement of strabismus (misalignment of the eyes; commonly referred to as a squint or lazy eye by the lay person). It is a quantitative and subjective method of measuring the size of a strabismic deviation by dissociation of the eyes brought ...

  8. Convergence insufficiency - Wikipedia

    en.wikipedia.org/wiki/Convergence_insufficiency

    Diagnosis of convergence insufficiency is made by an eye care professional skilled in binocular vision dysfunctions, such as an optometrist, opthomologist, or orthoptist to rule out any organic disease. Convergence insufficiency is characterized by one or more of the following diagnostic findings: patient symptoms, high exophoria at near, reduced accommodative convergence / accommodation ratio ...

  9. Anisometropia - Wikipedia

    en.wikipedia.org/wiki/Anisometropia

    Anisometropia is caused by common refractive errors, such as astigmatism, far-sightedness, and myopia, in one eye. [6] Anisometropia is likely the result of both genetic and environmental influences. [7] Some studies suggest, in older adults, developing asymmetric cataracts may cause worsen anisometropia.

  10. Heterophoria - Wikipedia

    en.wikipedia.org/wiki/Heterophoria

    Heterophoria is an eye condition in which the directions that the eyes are pointing at rest position, when not performing binocular fusion, are not the same as each other, or, "not straight". This condition can be esophoria, where the eyes tend to cross inward in the absence of fusion; exophoria, in which they diverge; or hyperphoria, in which ...

  11. Corrective Optics Space Telescope Axial Replacement

    en.wikipedia.org/wiki/Corrective_Optics_Space...

    The Corrective Optics Space Telescope Axial Replacement ( COSTAR) is an optical correction instrument designed and built by NASA. It was created to correct the spherical aberration of the Hubble Space Telescope ' s primary mirror, which incorrectly focused light upon the Faint Object Camera (FOC), Faint Object Spectrograph (FOS), and Goddard High Resolution Spectrograph (GHRS) instruments. [1]