enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Worth 4 dot test - Wikipedia

    en.wikipedia.org/wiki/Worth_4_dot_test

    It can be used to establish whether a patient has the ability for the eyes to fuse the light that is received from each eye into 4 lights. The test is indicated with the use of a presence of a prism in individuals with a strabismus and fusion is considered present if 4 lights are maintained, with or without the use of a prism. The W4LT can also ...

  3. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Prism correction is measured in prism dioptres. A prescription that specifies prism correction will also specify the "base". The base is the thickest part of the lens and is opposite from the apex. Light will be bent towards the base and the image will be shifted towards the apex.

  4. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    If the patient saw a red line to the right and white light to the left, they are said to have esotropia or esophoria (uncrossed diplopia) in which base out (BO) prisms of increasing strength are used until the lines are superimposed.

  5. Maddox wing - Wikipedia

    en.wikipedia.org/wiki/Maddox_Wing

    Relaxation of accommodation can result in an increase in exophoria and a decrease in esophoria, leading to an inaccurate result. The examiner should check the function of the Maddox Wing Instrument before use; the septa can be easily bent, leading to the septa not covering the intended view.

  6. Strabismus surgery - Wikipedia

    en.wikipedia.org/wiki/Strabismus_surgery

    Esotropias measuring more than 15 prism diopters (PD) and exotropias more than 20 PD that have not responded to refractive correction can be considered candidates for surgery. Techniques Disinserting the medial rectus muscle. The goal of strabismus surgery is to correct misalignment of the eyes.

  7. Cover test - Wikipedia

    en.wikipedia.org/wiki/Cover_test

    If the eye was exotropic, covering the fixating eye will cause an inwards movement; and if esotropic, covering the fixating eye will cause an outwards movement. The alternating cover test, or cross cover test is used to detect total deviation (tropia + phoria).

  8. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  9. Target, McDonald's and others are offering value as they lose ...

    www.aol.com/news/target-mcdonalds-others...

    Those items became part of Dealworthy, a new private brand launched in February that offers Target’s lowest prices on basic items like laundry detergent and paper plates.

  10. Four prism dioptre reflex test - Wikipedia

    en.wikipedia.org/wiki/Four_prism_dioptre_reflex_test

    The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion.

  11. Strabismus - Wikipedia

    en.wikipedia.org/wiki/Strabismus

    Strabismus. Strabismus is a vision disorder in which the eyes do not properly align with each other when looking at an object. [2] The eye that is pointed at an object can alternate. [3] The condition may be present occasionally or constantly. [3]