Ads
related to: eye prism correction device reviews youtube
Search results
Results from the WOW.Com Content Network
Tonometry is the procedure that eye care professionals perform to determine the intraocular pressure (IOP), the fluid pressure inside the eye. It is an important test in the evaluation of patients at risk from glaucoma.
The Maddox Wing is an instrument utilized by ophthalmologists, orthoptists and optometrists in the measurement of strabismus (misalignment of the eyes; commonly referred to as a squint or lazy eye by the lay person).
The optical quality of the eye is limited by optical aberrations, diffraction and scatter. [1] Correction of spherocylindrical refractive errors has been possible for nearly two centuries following Airy's development of methods to measure and correct ocular astigmatism.
The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion.
Maddox rod. The Maddox rod test can be used to subjectively detect and measure a latent, manifest, horizontal or vertical strabismus for near and distance. The test is based on the principle of diplopic projection. [1]
Dielectric phase-correction prism coatings are applied in a vacuum chamber with maybe thirty or more different superimposed vapor coating layers deposits, making it a complex production process.
Abbe refractometer. Sketch of an Abbe refractometer with temperature-controlled prisms. An Abbe refractometer, manufactured by Zeiss around 1920. Note that the thermometer is not attached. An Abbe refractometer is a bench-top device for the high-precision measurement of an index of refraction .
A phakic intraocular lens (PIOL) is an intraocular lens that is implanted surgically into the eye to correct refractive errors without removing the natural lens (also known as "phakos", hence the term).
Aberration can be defined as a departure of the performance of an optical system from the predictions of paraxial optics. [2] In an imaging system, it occurs when light from one point of an object does not converge into (or does not diverge from) a single point after transmission through the system.
The pibal theodolite uses a prism to bend the optical path by 90 degrees so the operator's eye position does not change as the elevation is changed through a complete 180 degrees. The theodolite is typically mounted on a rugged steel stand, set up so it is level and pointed north, with the altitude and azimuth scales reading zero degrees.