enow.com Web Search

Search results

    15.09+0.45 (+3.07%)

    at Fri, May 31, 2024, 4:00PM EDT - U.S. markets closed

    Nasdaq Real Time Price

    • Open 14.77
    • High 15.21
    • Low 14.64
    • Prev. Close 14.64
    • 52 Wk. High 27.02
    • 52 Wk. Low 13.71
    • P/E N/A
    • Mkt. Cap 1.19B
  1. Results from the WOW.Com Content Network
  2. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  3. Prism fusion range - Wikipedia

    en.wikipedia.org/wiki/Prism_fusion_range

    The prism fusion range (PFR) or fusional vergence amplitude is a clinical eye test performed by orthoptists, optometrists, and ophthalmologists to assess motor fusion, specifically the extent to which a patient can maintain binocular single vision in the presence of increasing vergence demands.

  4. Four prism dioptre reflex test - Wikipedia

    en.wikipedia.org/wiki/Four_prism_dioptre_reflex_test

    Four prism dioptre reflex test. Purpose. assess alignment of both eyes. The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion. [1]

  5. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    The test is based on the principle of diplopic projection. Dissociation of the deviation is brought about by presenting a red line image to one eye and a white light to the other, while prisms are used to superimpose these and effectively measure the angle of deviation (horizontal and vertical).

  6. Hirschberg test - Wikipedia

    en.wikipedia.org/wiki/Hirschberg_test

    In the fields of optometry and ophthalmology, the Hirschberg test, also Hirschberg corneal reflex test, is a screening test that can be used to assess whether a person has strabismus (ocular misalignment). A photographic version of the Hirschberg is used to quantify strabismus.

  7. Humphrey visual field analyser - Wikipedia

    en.wikipedia.org/wiki/Humphrey_Visual_Field_Analyser

    Humphrey visual field analyser. Humphrey field analyser ( HFA) is a tool for measuring the human visual field that is commonly used by optometrists, orthoptists and ophthalmologists, particularly for detecting monocular visual field. [1] The results of the analyser identify the type of vision defect.

  8. Cover test - Wikipedia

    en.wikipedia.org/wiki/Cover_test

    A cover test or cover-uncover test is an objective determination of the presence and amount of ocular deviation. It is typically performed by orthoptists, ophthalmologists and optometrists during eye examinations . The two primary types of cover tests are: the alternating cover test. the unilateral cover test (or the cover-uncover test).

  9. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Prism dioptres. Prism correction is commonly specified in prism dioptres, a unit of angular measurement that is loosely related to the dioptre. Prism dioptres are represented by the Greek symbol delta (Δ) in superscript. A prism of power 1 Δ would produce 1 unit of displacement for an object held 100 units from the prism. [2]

  10. Fixation disparity - Wikipedia

    en.wikipedia.org/wiki/Fixation_disparity

    Observers with a fixation disparity are more likely to report eye strain in demanding visual tasks; therefore, tests of fixation disparity belong to the diagnostic tools used by eye care professionals: remediation includes vision therapy, prism eye glasses, or visual ergonomics at the workplace.

  11. Keratometer - Wikipedia

    en.wikipedia.org/wiki/Keratometer

    Keratometer. A keratometer, also known as an ophthalmometer, is a diagnostic instrument for measuring the curvature of the anterior surface of the cornea, particularly for assessing the extent and axis of astigmatism. It was invented by the German physiologist Hermann von Helmholtz in 1851, although an earlier model was developed in 1796 by ...