enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Four prism dioptre reflex test - Wikipedia

    en.wikipedia.org/wiki/Four_prism_dioptre_reflex_test

    4 dioptre prism, either loose or prism bar; Bright lighting conditions; Method of assessment. As it is an objective test, few instructions are required to be given to the patient. The patient is asked to fixate on a target while the examiner places a 4 prism dioptre base-out prism over the patient's eye, observing the response of the fellow eye.

  3. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  4. Hirschberg test - Wikipedia

    en.wikipedia.org/wiki/Hirschberg_test

    Purpose. whether a person has strabismus. In the fields of optometry and ophthalmology, the Hirschberg test, also Hirschberg corneal reflex test, is a screening test that can be used to assess whether a person has strabismus (ocular misalignment). A photographic version of the Hirschberg is used to quantify strabismus. [1]

  5. Alkali–silica reaction - Wikipedia

    en.wikipedia.org/wiki/Alkali–silica_reaction

    The alkali–silica reaction ( ASR ), also commonly known as concrete cancer, [3] is a deleterious internal swelling reaction that occurs over time in concrete between the highly alkaline cement paste and the reactive amorphous ( i.e., non-crystalline) silica found in many common aggregates, given sufficient moisture.

  6. Conservation and restoration of lighthouses - Wikipedia

    en.wikipedia.org/wiki/Conservation_and...

    Documentation of the prism normally begins with labeling all issues starting from the center prism, listed as number one, and then working outward sequentially. Identification should indicate whether it is an upper or lower prism. Prisms are checked for firm seating by gently tapping on the outside of the glass only. If there is any movement of ...

  7. Three-point flexural test - Wikipedia

    en.wikipedia.org/wiki/Three-point_flexural_test

    The three-point bending flexural test provides values for the modulus of elasticity in bending , flexural stress , flexural strain and the flexural stress–strain response of the material. This test is performed on a universal testing machine (tensile testing machine or tensile tester) with a three-point or four-point bend fixture.

  8. Four-point flexural test - Wikipedia

    en.wikipedia.org/wiki/Four-point_flexural_test

    The four-point flexural test provides values for the modulus of elasticity in bending , flexural stress , flexural strain and the flexural stress-strain response of the material. This test is very similar to the three-point bending flexural test. The major difference being that with the addition of a fourth bearing the portion of the beam ...

  9. Flow table test - Wikipedia

    en.wikipedia.org/wiki/Flow_table_test

    The cone filled with concrete, prior to lifting. The diameter of the resulting flow is measured. The flow table test or slump-flow test is a method to determine consistency of fresh concrete. Flow table test is also used to identify transportable moisture limit of solid bulk cargoes. [1] It is used primarily for assessing concrete that is too ...