The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]
Prism correction. Prism lenses (here unusually thick) are used for pre-operative prism adaptation. Eye care professionals use prism correction as a component of some eyeglass prescriptions. A lens which includes some amount of prism correction will displace the viewed image horizontally, vertically, or a combination of both directions.
Whilst holding the spherical lenses on the confirmation set centrally in front of the patient's eye, the clinician asks the patient: "Is it clearer with, or without the lens?" Adjust the spherical component by adding, increasing and refining the power as required. Initially, adjust by 0.50DS, then refine with 0.25DS.
Grade 4 anterior chamber angle. open angle between cornea and iris. AC 3/4. Grade 3 anterior chamber angle. AC 2/4. Grade 2 anterior chamber angle. AC 1/4. Grade 1 anterior chamber angle. AC 0/4.
Cover test. A cover test or cover-uncover test is an objective determination of the presence and amount of ocular deviation. It is typically performed by orthoptists, ophthalmologists and optometrists during eye examinations . The two primary types of cover tests are: the unilateral cover test (or the cover-uncover test).
The lamp facilitates an examination of the anterior segment and posterior segment of the human eye, which includes the eyelid, sclera, conjunctiva, iris, natural crystalline lens, and cornea. The binocular slit-lamp examination provides a stereoscopic magnified view of the eye structures in detail, enabling anatomical diagnoses to be made for a ...
The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion.
Because instruments such as binoculars and microscopes can be used by different people, the distance between the eye pieces is usually made adjustable to account for IPD. In some applications, when IPD is not correctly set, it can lead to an uncomfortable viewing experience and eye strain. Measuring pupillary distance
Refractive surgery. Refractive surgery is optional eye surgery used to improve the refractive state of the eye and decrease or eliminate dependency on glasses or contact lenses. This can include various methods of surgical remodeling of the cornea ( keratomileusis ), lens implantation or lens replacement.
The prism fusion range (PFR) or fusional vergence amplitude is a clinical eye test performed by orthoptists, optometrists, and ophthalmologists to assess motor fusion, specifically the extent to which a patient can maintain binocular single vision in the presence of increasing vergence demands.