enow.com Web Search

  1. Ad

    related to: hypertropia prism correction test kit

Search results

  1. Results from the WOW.Com Content Network
  2. Worth 4 dot test - Wikipedia

    en.wikipedia.org/wiki/Worth_4_dot_test

    assess degree of binocular vision. The Worth Four Light Test, also known as the Worth's four dot test or W4LT, is a clinical test mainly used for assessing a patient's degree of binocular vision and binocular single vision. Binocular vision involves an image being projected by each eye simultaneously into an area in space and being fused into a ...

  3. Cyclotropia - Wikipedia

    en.wikipedia.org/wiki/Cyclotropia

    Cyclotropia is a form of strabismus in which, compared to the correct positioning of the eyes, there is a torsion of one eye (or both) about the eye's visual axis. Consequently, the visual fields of the two eyes appear tilted relative to each other. The corresponding latent condition – a condition in which torsion occurs only in the absence ...

  4. Šidák correction for t-test - Wikipedia

    en.wikipedia.org/wiki/Šidák_correction_for_t-test

    Šidák correction for t-test. One of the application of Student's t-test is to test the location of one sequence of independent and identically distributed random variables. If we want to test the locations of multiple sequences of such variables, Šidák correction should be applied in order to calibrate the level of the Student's t-test.

  5. Dissociated vertical deviation - Wikipedia

    en.wikipedia.org/wiki/Dissociated_vertical_deviation

    A test called the Bielschowsky Darkening Wedge Test can be used to reveal and diagnose the presence of dissociated vertical deviation, although any (or no) amount of dissociative occlusion may also prompt it to occur. The patient is asked to look at a light. One eye is covered and a filter is placed in front of the other eye.

  6. Four prism dioptre reflex test - Wikipedia

    en.wikipedia.org/wiki/Four_prism_dioptre_reflex_test

    Purpose. assess alignment of both eyes. The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion. [1] Through the use of a 4 dioptre base out prism ...

  7. UMPK (bomb kit) - Wikipedia

    en.wikipedia.org/wiki/UMPK_(bomb_kit)

    UMPK (bomb kit) UMPK ( Russian: УМПК; Унифицированный модуль планирования и коррекции; Unified gliding and correction module) is a guidance kit first developed by the Russian Bazalt Design Bureau for converting unguided Soviet bombs into precision-guided munitions. This kit is an aerial bomb glide ...

  8. Parks–Bielschowsky three-step test - Wikipedia

    en.wikipedia.org/wiki/Parks–Bielschowsky_three...

    Bielschowsky's head tilt test. Step 1: Determine which eye is hypertropic in primary position. If there is right hypertropia in primary position, then the depressors of the R eye (IR/SO) or the elevators of the L eye are weak (SR/IO). Step 2: Determine whether the hypertropia increases on right or left gaze.

  9. COVID-19 rapid antigen test - Wikipedia

    en.wikipedia.org/wiki/COVID-19_rapid_antigen_test

    The World Health Organization (WHO) COVID-19 Case Definition states that a person with a positive RAT (also known as an antigen rapid diagnostic test or Antigen-RDT) can be considered a "confirmed case of SARS-CoV-2 infection" in two ways. [10] First, the person with a positive Antigen-RDT could meet a "probable case definition" such as having ...

  1. Ad

    related to: hypertropia prism correction test kit