The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]
Prism correction is measured in prism dioptres. A prescription that specifies prism correction will also specify the "base". The base is the thickest part of the lens and is opposite from the apex. Light will be bent towards the base and the image will be shifted towards the apex.
Prism and Base Prism refers to a displacement of the image through the lens, often used to treat strabismus and other binocular vision disorders. The prism value is measured in prism diopters , and Base refers to the direction of displacement.
The prism fusion range (PFR) or fusional vergence amplitude is a clinical eye test performed by orthoptists, optometrists, and ophthalmologists to assess motor fusion, specifically the extent to which a patient can maintain binocular single vision in the presence of increasing vergence demands.
The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion.
Hirschberg corneal reflex test. Purpose. whether a person has strabismus. In the fields of optometry and ophthalmology, the Hirschberg test, also Hirschberg corneal reflex test, is a screening test that can be used to assess whether a person has strabismus (ocular misalignment).
Tonometry is the procedure that eye care professionals perform to determine the intraocular pressure (IOP), the fluid pressure inside the eye. It is an important test in the evaluation of patients at risk from glaucoma . [1]
To measure RMS for each type of aberration involves squaring the difference between the aberration and mean value and averaging it across the pupil area. Different kinds of aberrations may have equal RMS across the pupil but have different effects on vision, therefore, RMS error is unrelated to visual performance.
A phoropter measurement of a patient reads −8.00 D sphere and −5.25 D cylinder with an axis of 85° for one eye (the notation for which is typically written as −8 −5.25×85). The phoropter measurement is made at a common vertex distance of 12 mm from the eye.
A Snellen chart is an eye chart that can be used to measure visual acuity. Snellen charts are named after the Dutch ophthalmologist Herman Snellen who developed the chart in 1862 as a measurement tool for the acuity formula developed by his professor Franciscus Cornelius Donders.