enow.com Web Search

  1. Ads

    related to: esophoria prism correction tape price per box

Search results

  1. Results from the WOW.Com Content Network
  2. Worth 4 dot test - Wikipedia

    en.wikipedia.org/wiki/Worth_4_dot_test

    It can be used to establish whether a patient has the ability for the eyes to fuse the light that is received from each eye into 4 lights. The test is indicated with the use of a presence of a prism in individuals with a strabismus and fusion is considered present if 4 lights are maintained, with or without the use of a prism. The W4LT can also ...

  3. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Prism dioptres. Prism correction is commonly specified in prism dioptres, a unit of angular measurement that is loosely related to the dioptre. Prism dioptres are represented by the Greek symbol delta (Δ) in superscript. A prism of power 1 Δ would produce 1 unit of displacement for an object held 100 units from the prism. [2]

  4. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    The strength of the prism is increased until the streak of the light passes through the centre of the prism, as the strength of the prism indicates the amount of deviation present. The Maddox rod is a handheld instrument composed of red parallel plano convex cylinder lens , which refracts light rays so that a point source of light is seen as a ...

  5. Esophoria - Wikipedia

    en.wikipedia.org/wiki/Esophoria

    Esophoria is an eye condition involving inward deviation of the eye, usually due to extra-ocular muscle imbalance. It is a type of heterophoria . Cause [ edit ]

  6. Cover test - Wikipedia

    en.wikipedia.org/wiki/Cover_test

    A cover test or cover-uncover test is an objective determination of the presence and amount of ocular deviation. It is typically performed by orthoptists, ophthalmologists and optometrists during eye examinations . The two primary types of cover tests are: the alternating cover test. the unilateral cover test (or the cover-uncover test).

  7. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  8. Prism (optics) - Wikipedia

    en.wikipedia.org/wiki/Prism_(optics)

    Prism (optics) An optical prism is a transparent optical element with flat, polished surfaces that are designed to refract light. At least one surface must be angled — elements with two parallel surfaces are not prisms. The most familiar type of optical prism is the triangular prism, which has a triangular base and rectangular sides.

  9. Strabismus - Wikipedia

    en.wikipedia.org/wiki/Strabismus

    Strabismus. Strabismus is a vision disorder in which the eyes do not properly align with each other when looking at an object. [2] The eye that is pointed at an object can alternate. [3] The condition may be present occasionally or constantly. [3]

  10. Prism adaptation - Wikipedia

    en.wikipedia.org/wiki/Prism_Adaptation

    Prism adaptation. Prism adaptation is a sensory-motor adaptation that occurs after the visual field has been artificially shifted laterally or vertically. It was first introduced by Hermann von Helmholtz in late 19th-century Germany as supportive evidence for his perceptual learning theory (Helmholtz, 1909/1962). [1]

  11. Bonferroni correction - Wikipedia

    en.wikipedia.org/wiki/Bonferroni_correction

    The Bonferroni correction compensates for that increase by testing each individual hypothesis at a significance level of , where is the desired overall alpha level and is the number of hypotheses. [4] For example, if a trial is testing hypotheses with a desired overall , then the Bonferroni correction would test each individual hypothesis at .