Search results
Results from the WOW.Com Content Network
The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]
It can be used to establish whether a patient has the ability for the eyes to fuse the light that is received from each eye into 4 lights. The test is indicated with the use of a presence of a prism in individuals with a strabismus and fusion is considered present if 4 lights are maintained, with or without the use of a prism. The W4LT can also ...
Other lower-order aberrations are non- visually significant aberrations known as first order aberrations, such as prisms and zero-order aberrations (piston). Low order aberrations account for approximately 90% of the overall wave aberration in the eye.
The Four Prism Dioptre Reflex Test (also known as the 4 PRT, or 4 Prism Dioptre Base-out Test) is an objective, non-dissociative test used to prove the alignment of both eyes (i.e. the presence of binocular single vision) by assessing motor fusion.
The extraocular muscle pulley system is fundamental to the movement of the eye muscles, in particular also to ensure conformity to Listing's law. Certain diseases of the pulleys (heterotopy, instability, and hindrance of the pulleys) cause particular patterns of incomitant strabismus.
A duochrome test is a test commonly used to refine the final sphere in refraction (undercorrection and overcorrection), which makes use of the longitudinal chromatic aberration of the eye. Because of the chromatic aberration of the eye, the shorter wavelengths (green) are focused in front of the longer red wavelengths.
The prism fusion range (PFR) or fusional vergence amplitude is a clinical eye test performed by orthoptists, optometrists, and ophthalmologists to assess motor fusion, specifically the extent to which a patient can maintain binocular single vision in the presence of increasing vergence demands.
A Snellen chart is an eye chart that can be used to measure visual acuity. Snellen charts are named after the Dutch ophthalmologist Herman Snellen who developed the chart in 1862 as a measurement tool for the acuity formula developed by his professor Franciscus Cornelius Donders .
Some cases of convergence insufficiency are successfully managed by prescription of eyeglasses, sometimes with therapeutic prisms. Pencil push-ups therapy is performed at home. The patient brings a pencil slowly to within 2–3 cm (0.79–1.18 in) of the eye just above the nose about fifteen minutes per day five times per week.
Prismatic, self-masking glasses are now being used by some cross-eyed-view advocates. These reduce the degree of convergence required and allow large images to be displayed. However, any viewing aid that uses prisms, mirrors or lenses to assist fusion or focus is simply a type of stereoscope, excluded by the customary definition of freeviewing.