enow.com Web Search

  1. Ads

    related to: esophoria prism correction tool for canon pixma mg3100

Search results

  1. Results from the WOW.Com Content Network
  2. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    The most common application for this is the treatment of strabismus. By moving the image in front of the deviated eye, double vision can be avoided and comfortable binocular vision can be achieved. Other applications include yoked prism where the image is shifted an equal amount in each eye.

  3. List of Canon products - Wikipedia

    en.wikipedia.org/wiki/List_of_Canon_products

    Canonflex R2000 (1960) – An upgrade with 1/2000 shutter speed (up from 1/1000) Canonflex RP (1960) – simplified Canonflex without the interchangeable prism/viewer. Canonflex RM (1962) – A redesign of the RP with builtin metering and a lower profile prism. Offered with an f/1.2 58mm lens option.

  4. Esotropia - Wikipedia

    en.wikipedia.org/wiki/Esotropia

    Where appropriate, prismatic correction can be used, either temporarily or permanently, to relieve symptoms of double vision. In specific cases, and primarily in adult patients, botulinum toxin can be used either as a permanent therapeutic approach, or as a temporary measure to prevent contracture of muscles prior to surgery

  5. Prism (optics) - Wikipedia

    en.wikipedia.org/wiki/Prism_(optics)

    Prism spectacles with a single prism perform a relative displacement of the two eyes, thereby correcting eso-, exo, hyper- or hypotropia. In contrast, spectacles with prisms of equal power for both eyes, called yoked prisms (also: conjugate prisms, ambient lenses or performance glasses) shift the visual field of both eyes to the same extent.

  6. Fixation disparity - Wikipedia

    en.wikipedia.org/wiki/Fixation_disparity

    Based on prism-FD curves (Fig. 3b), one can find the aligning prism sP 0 that nullifies the naturally prevailing fixation disparity sFD 0. This test procedure is typically made in near vision of 40 cm, e.g. with the Mallett-unit, the Disparometer, or the Wesson card (see above).

  7. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    If the patient saw a red line to the right and white light to the left, they are said to have esotropia or esophoria (uncrossed diplopia) in which base out (BO) prisms of increasing strength are used until the lines are superimposed.

  8. Distortion (optics) - Wikipedia

    en.wikipedia.org/wiki/Distortion_(optics)

    GIMP includes manual lens distortion correction (from version 2.4). PhotoPerfect has interactive functions for general pincushion adjustment, and for fringe (adjusting the size of the red, green and blue image parts).

  9. Horror fusionis - Wikipedia

    en.wikipedia.org/wiki/Horror_fusionis

    When the eye position is fully corrected (for example after surgical alignment of the eyes) or when the patient is provided with the best achievable prism correction, the patient does not experience binocular fusion and, instead, sees a double image that is very close to the fixation image and is perceived as "dancing around" it.

  10. Optical proximity correction - Wikipedia

    en.wikipedia.org/wiki/Optical_proximity_correction

    Optical proximity correction (OPC) is a photolithography enhancement technique commonly used to compensate for image errors due to diffraction or process effects. The need for OPC is seen mainly in the making of semiconductor devices and is due to the limitations of light to maintain the edge placement integrity of the original design, after ...

  11. Flat-field correction - Wikipedia

    en.wikipedia.org/wiki/Flat-field_correction

    Flat-field correction ( FFC) is a digital imaging technique to mitigate the image detector pixel-to-pixel sensitivity and distortions in the optical path. It is a standard calibration procedure in everything from personal digital cameras to large telescopes.