enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  3. Hypertropia - Wikipedia

    en.wikipedia.org/wiki/Hypertropia

    Surgical correction; Surgical correction of the hypertropia is desired to achieve binocularity, manage diplopia and/or correct the cosmetic defect. Steps to achieve the same depend on mechanism of the hypertropia and identification of the offending muscles causing the misalignment.

  4. List of optometric abbreviations - Wikipedia

    en.wikipedia.org/wiki/List_of_optometric...

    List of optometric abbreviations. Certain abbreviations are current within the profession of optometry. They are used to denote clinical conditions, examination techniques and findings, and various forms of treatment.

  5. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    If the patient saw a red line to the right and white light to the left, they are said to have esotropia or esophoria (uncrossed diplopia) in which base out (BO) prisms of increasing strength are used until the lines are superimposed.

  6. Parks–Bielschowsky three-step test - Wikipedia

    en.wikipedia.org/wiki/Parks–Bielschowsky_three...

    Step 1: Determine which eye is hypertropic in primary position. If there is right hypertropia in primary position, then the depressors of the R eye (IR/SO) or the elevators of the L eye are weak (SR/IO). Step 2: Determine whether the hypertropia increases on right or left gaze.

  7. Hirschberg test - Wikipedia

    en.wikipedia.org/wiki/Hirschberg_test

    For an abnormal result, based on where the light lands on the cornea, the examiner can detect if there is an exotropia (abnormal eye is turned out), esotropia (abnormal eye is turned in), hypertropia (abnormal eye higher than the normal one) or hypotropia (abnormal eye is lower than the normal one).

  8. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Prism correction is measured in prism dioptres. A prescription that specifies prism correction will also specify the "base". The base is the thickest part of the lens and is opposite from the apex. Light will be bent towards the base and the image will be shifted towards the apex.

  9. Bagolini Striated Glasses Test - Wikipedia

    en.wikipedia.org/wiki/Bagolini_Striated_Glasses_Test

    Hypertropia/Hypotropia. In a patient with an unsuppressed vertical deviation, one line will appear higher than the other. If the image of the right eye is higher than that of the left, this means the right eye is lower than the left. This could be either a right hypotropia or a left hypertropia. Harmonious Abnormal retinal correspondence

  10. Prentice position - Wikipedia

    en.wikipedia.org/wiki/Prentice_position

    The Prentice position is an orientation of a prism, used in optics, optometry and ophthalmology. In this position, named after the optician Charles F. Prentice, the prism is oriented such that light enters it at an angle of 90° to the first surface, so that the beam does not refract at that surface. All the deviation caused by the prism takes ...

  11. Prism (optics) - Wikipedia

    en.wikipedia.org/wiki/Prism_(optics)

    Prism spectacles with a single prism perform a relative displacement of the two eyes, thereby correcting eso-, exo, hyper- or hypotropia. In contrast, spectacles with prisms of equal power for both eyes, called yoked prisms (also: conjugate prisms , ambient lenses or performance glasses ) shift the visual field of both eyes to the same extent.