enow.com Web Search

Search results

    122.91-2.03 (-1.62%)

    at Wed, May 29, 2024, 1:54PM EDT - U.S. markets close in 2 hours 6 minutes

    Nasdaq Real Time Price

    • Open 123.70
    • High 123.70
    • Low 119.05
    • Prev. Close 124.94
    • 52 Wk. High 164.00
    • 52 Wk. Low 46.50
    • P/E 423.83
    • Mkt. Cap 127.87B
  1. Results from the WOW.Com Content Network
  2. Hypertropia - Wikipedia

    en.wikipedia.org/wiki/Hypertropia

    Surgical correction; Surgical correction of the hypertropia is desired to achieve binocularity, manage diplopia and/or correct the cosmetic defect. Steps to achieve the same depend on mechanism of the hypertropia and identification of the offending muscles causing the misalignment.

  3. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    measuring strabismus. The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  4. List of optometric abbreviations - Wikipedia

    en.wikipedia.org/wiki/List_of_optometric...

    Left hypertropia LHypoT: Left hypotropia LO: Lenticular opacity L/R FD: L/R fixation disparity L/R: L hyperphoria Left ET: Left esotropia LVA: Low vision aid MDU: Mallett distance unit MNU: Mallett near unit M.Wing: Maddox Wing: MR: Maddox rod NB: NAD: No abnormality detected (is frequently used but is not recommended) NCT: Non-contact ...

  5. Heterophoria - Wikipedia

    en.wikipedia.org/wiki/Heterophoria

    When the visual axis is misaligned in such a way, it is corrected by the fusional vergence system. Diagnosis. The cross-cover test, or alternating cover test is usually employed to detect heterophoria. One eye is covered, and then the cover is moved immediately over to the other eye.

  6. Cyclotropia - Wikipedia

    en.wikipedia.org/wiki/Cyclotropia

    In several cases of double vision, once the underlying cyclotropia was identified, the condition was solved by surgical cyclotropia correction. [4] Conversely, artificially causing cyclotropia in cats leads to reduced vision acuity, resulting in a defect similar to strabismic amblyopia .

  7. Prism correction - Wikipedia

    en.wikipedia.org/wiki/Prism_correction

    Prism correction is measured in prism dioptres. A prescription that specifies prism correction will also specify the "base". The base is the thickest part of the lens and is opposite from the apex. Light will be bent towards the base and the image will be shifted towards the apex.

  8. Worth 4 dot test - Wikipedia

    en.wikipedia.org/wiki/Worth_4_dot_test

    The test is indicated with the use of a presence of a prism in individuals with a strabismus and fusion is considered present if 4 lights are maintained, with or without the use of a prism. The W4LT can also be indicated when aiding a person to develop and strengthen their fusional capacities.

  9. Hirschberg test - Wikipedia

    en.wikipedia.org/wiki/Hirschberg_test

    In hypertropia the light lands on the inferior aspect of the cornea. In hypotropia the light lands on the superior aspect of the cornea. A cover test can tell you the extent of the eso/exo-tropia. Individuals can suffer from several tropias at once.

  10. Parks–Bielschowsky three-step test - Wikipedia

    en.wikipedia.org/wiki/Parks–Bielschowsky_three...

    Step 1: Determine which eye is hypertropic in primary position. If there is right hypertropia in primary position, then the depressors of the R eye (IR/SO) or the elevators of the L eye are weak (SR/IO).

  11. Twyman–Green interferometer - Wikipedia

    en.wikipedia.org/wiki/Twyman–Green_interferometer

    Twyman–Green interferometer. A Twyman–Green interferometer is a variant of the Michelson interferometer principally used to test optical components. [1] It was introduced in 1918 by Frank Twyman [2] [3] and Arthur Green. Fig. 1 illustrates a Twyman–Green interferometer set up to test a lens.